Gems Sensors & Controls 4100+
Gems Sensors & Controls

4100+ Plus Series 1/4 DIN advanced temperature controller

Process & PID controllers

Manufacturer
Gems Sensors & Controls
Model
4100+
Instrument type
Process & PID controllers
Format
1/4 DIN panel controller
Input
Universal: thermocouple, RTD, mA, voltage; jumperless configuration
Supply voltage
100–240 VAC or 24–48 V AC/DC
Output slot 1
Relay, SSR driver, triac or linear (mA, V; 0–10 V default)
Output slot 2
Relay, SSR driver, triac or linear (4–20 mA default)
Output slot 3
Relay, SSR driver, linear or transmitter power supply
Option slot A
RS-485 serial communication, digital input or basic remote setpoint
Option slot B
Full remote setpoint with digital input 2
Setpoints
Dual, with optional remote selection
Alarms
Process and loop alarms with adjustable hysteresis
Transmitter supply
24 VDC
Display
Two-line, red/green upper and lower (four combinations)
Compatibility
Panel cutout, housing and wiring backward-compatible with N4100
Request a quote
Review enquiry

The 4100+ is a 1/4 DIN temperature controller of the Plus Series, developed from the earlier N4100. It is designed for demanding industrial and process control applications and offers enhanced flexibility and ease of use.

The controller accepts a universal input for thermocouples, RTDs, mA and voltage signals. Input configuration is jumperless, and the controller recognises installed hardware automatically; according to the manufacturer, this reduces setup time by up to 50 %. Dual setpoints are provided, with optional remote selection, and an optional analogue remote setpoint input allows the setpoint to be given by an external signal. Process and loop alarms with adjustable hysteresis are included. The operator interface (HMI) can be customised, and the user can select between expanded operator modes.

Outputs are realised with plug-in, user-selectable modules. Option slot 1 accepts a relay, SSR driver, triac or linear output (mA or V, 0–10 V DC by default). Option slot 2 accepts a relay, SSR driver, triac or linear output (4–20 mA by default). Option slot 3 accepts a relay, SSR driver, linear output (4–20 mA default) or a 24 VDC transmitter power supply. Option slot A can be fitted with RS-485 serial communication, a digital input or a basic remote setpoint, and option slot B with a full remote setpoint including digital input 2.

The controller is available for a supply of 100–240 VAC or 24–48 V AC/DC. The two-line display is available in four colour combinations: red upper and red lower, green upper and green lower, red upper and green lower, or green upper and red lower.

The panel cutout, housing and terminal wiring are backward-compatible with the previous model. A large number of configured part numbers (P4101Z…) is listed for combinations of supply, display and option slots.

The applications named for the 4100+ are industrial temperature control and process control.

When enquiring, please state the input type, supply voltage, required outputs for each slot, communication or remote setpoint options and display colour, or the full part number.

Part numbers · 25

P4101Z27010000, P4101Z22000200, P4101Z21070000, P4101Z27170000, P4101Z22101200, P4101Z22201020, P4101Z21000000, P4101Z27700000, P4101Z27100020, P4101Z21100010, P4101Z27183030, P4101Z27110200, P4101Z27100000, P4101Z22110020, P4101Z2111302R, P4101Z21700000, P4101Z2110100R, P4101Z27170020, P4101Z2712003R, P4101Z27000020S15, P4101Z21001000, P4101Z2771300R, P4101Z22700000, P4101Z22000000, P4101Z27001000

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.