The 54 II is a dual-input digital thermometer with data logging, designed for laboratory accuracy in industrial use. It works with external thermocouples as temperature sensors, displays two measuring points and their difference, stores readings in memory and transfers them to a PC over an infrared link.
The microprocessor-based instrument accepts J, K, T, E, R, S and N thermocouples. The two inputs T1 and T2 can be shown individually or as the differential T1–T2 on a large backlit dual display. Readings are displayed in °C, °F or kelvin. An electronic offset function compensates for the error of a specific probe and so improves the overall accuracy of the measurement.
Measuring ranges depend on the thermocouple type: −210 to 1200 °C for type J, −200 to 1372 °C for K, −250 to 400 °C for T, −150 to 1000 °C for E, −200 to 1300 °C for N and 0 to 1767 °C for R and S. Above −100 °C the accuracy for J, K, T, E and N is ±(0.05 % + 0.3 °C), and for R and S ±(0.05 % + 0.4 °C). Below −100 °C the accuracy is ±(0.20 % + 0.3 °C) for J, K, E and N and ±(0.50 % + 0.3 °C) for T. Resolution is 0.1 °C below 1000 and 1 °C above. Temperature measurement refers to ITS-90.
Up to 500 data points are logged to internal memory at user-adjustable intervals and can be recalled on the display. Through the infrared USB communication port the data is exported to PC temperature software for analysis and documentation, for example for ISO 9000 records.
The case is splash and dust resistant. The thermometer measures 173 × 86 × 38 mm, weighs 400 g and operates from −10 to 50 °C. It is designed to EN/IEC 61010-1 and EN/IEC 61326-1 and carries UL certification. An optional ToolPak lets the instrument hang from a metal object or be secured around a pipe for hands-free work.
Accessories include PC temperature software, the ToolPak, holster and flex stand, cases and thermocouple probes such as the 80PK-1 K-type bead thermocouple. A single-input version (53 II B) is also part of the series.
Typical tasks are checking motors, insulation, breakers, pipes, corroded connections, liquids and wires, industrial temperature monitoring, process monitoring, calibration and testing. Please tell us which thermocouple probes and accessories you need together with the thermometer.
54 II, 80PK-1, 773135, 1272438, 376756, 1276106, 1276123, FVF-SC2
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.