UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Signal conditioners & barriers
The DMD-465 and DMD-466 are self-contained signal conditioning modules for strain gauges, load cells and other bridge-type sensors. They supply the bridge with excitation voltage, amplify the small bridge signal with a precision differential instrumentation amplifier and deliver a high-level voltage or current output.
The modules accommodate bridge circuits of 120 Ω, 350 Ω, 500 Ω and greater, connected with six wires. The 6-wire connection uses separate sense lines, so voltage drops in long cables do not affect the excitation at the bridge. Excitation is adjustable from 4 to 15 V DC and can supply up to 120 mA. Full-scale input signals from 10 mV to 50 mV are accepted; the input resistance is 3000 MΩ with an input bias current of 30 nA.
Gain is adjustable from 40 to 250, or up to 1000 with an external resistor, and offset is also adjustable, so the output can be scaled to the sensor and to the required zero. Linearity is ±0.05 % of full scale, and output noise is as low as 0.5 mVrms.
The DMD-465 provides a ±10 V DC voltage output into loads of 2 kΩ or more, with an output impedance of 0.01 to 1 Ω. The DMD-466 is a transmitter with a 4–20 mA or 0–20 mA current output and a maximum loop resistance of 500 Ω. The DMD-465WB is a high-frequency variant with a bandwidth from DC to 2 kHz for faster signals.
The standard modules are powered from 115 V AC; versions for 220 V AC (suffix -220V) and a DC-powered version (DMD-466-DC) are available. The compact housing measures 96 × 51 × 73 mm. Operating temperature is 0 to 70 °C and storage temperature −25 to 85 °C. The modules are CE marked.
To select the right model, please tell us the sensor type and bridge resistance, its sensitivity, the required output signal and bandwidth, and the available supply voltage.
DMD-465, DMD-465-220V, DMD-465WB, DMD-465WB-220V, DMD-466, DMD-466-220V, DMD-466-DC
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.