EDT 96
Pressure

Pressure transmitters
The EDT 23 is a miniature, precise pressure transducer for measuring the pressure of liquid and gaseous media. It is characterised by high accuracy, long-term stability and very low power consumption, and it is designed for integration into modern digital systems such as data loggers, gas-volume conversion devices and telemetric systems.
The transducer communicates through an RS-485 digital interface using the Modbus protocol. A measurement can be performed on request from the host device or automatically at set time intervals. The measured values are stored in the internal memory of the transducer, from which they can be read later, and the device is configured through the same interface.
Gauge pressure ranges are available from 0–10 kPa up to 0–7000 kPa, and absolute pressure ranges from 80–520 kPa up to 1400–7000 kPa. The accuracy is ±0.1 % of the range or ±0.25 % of the measured value. Gauge ranges measure pressure relative to the surrounding atmosphere, while absolute ranges measure relative to vacuum; both groups are offered in several steps, so the range can be matched to the application.
Power consumption is very low: 10 µA in the idle condition and 1 mA during operation, with a supply voltage starting from 2.9 V.
The case is made of resistant stainless steel. The transducer is approved for installation in hazardous areas with the marking II 2G Ex ia IIC T4 Gb and carries CE marking. The marking indicates equipment group II, category 2 for gas atmospheres, intrinsic safety level ia, gas group IIC and temperature class T4.
Typical applications are data loggers, gas-volume conversion devices and telemetric systems, and in general the integration of pressure measurement into modern digital systems in areas with or without explosion hazard.
When requesting an offer, please state whether gauge or absolute pressure is required, the measuring range, the medium and the quantity.
Specify whether the reference is gauge, absolute or differential pressure. Include the normal span and the largest pressure the instrument may see.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.