
GE14
Motion and position feedback

Industrial inclinometers
The JBC series are dynamic inclination sensors with IO-Link for moving and driving applications where space and weight are limited but high performance is required. Typical machines are fork-lift trucks (fork inclination, lift mast position, tipping prevention), mini excavators (attachment positioning, roll-over protection) and lifting platforms (alignment and calculation of lift height).
The JBC combines 3D acceleration and 3D gyroscope data, six degrees of freedom in total, using a Kalman filter algorithm. This sensor fusion detects and compensates for vibrations, shocks and rotational movements in real time and outputs precise, delay-free angle values for roll and pitch, also while the machine is moving.
The measuring range is −90° to +90° per axis, and the sensor can be used freely over 360°. Static accuracy is ≤ ±0.25° and dynamic accuracy ≤ ±0.5°, with a repeatability of ±0.05° and a resolution of 0.01°. The sensors are factory calibrated. Besides the angles, raw data such as acceleration, rotation rate and temperature are available.
Four models are offered. The JBC334 (horizontal mounting) and JBC234 (vertical mounting) have two switching outputs, and the JBC304 (horizontal) and JBC204 (vertical) have two 4–20 mA analogue outputs. All versions communicate via IO-Link, which is used for parameter setting and for reading the angle and raw data. The installation angle is variable, and the zero point can be set by the inductive teach surface on the housing or via the interface.
The compact plastic housing weighs less than 20 g and is fixed with two M4 Torx screws. Protection ratings are IP6K5, IP6K7, IP6K8 and IP6K9K, covering dust, immersion and high-pressure cleaning.
Please tell us the mounting orientation, the required output type and the angle range of your application when you request a quotation.
JBC234, JBC334, JBC204, JBC304
Compare the shaft or scale mounting, resolution and electrical interface with the receiving controller. For a replacement, record the connector, reference mark and direction of travel.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.