DwyerOmega OME-ET-7000 / OME-PET-7000
DwyerOmega

OME-ET-7000 / OME-PET-7000 Ethernet remote I/O modules with web server

I/O modules

Manufacturer
DwyerOmega
Model
OME-ET-7000 / OME-PET-7000
Instrument type
I/O modules
Network
Ethernet 10/100Base-TX
Protocols
Modbus TCP, Modbus UDP
Web server
built-in, web HMI
Power
PoE IEEE 802.3af (PET models); terminal block (ET models)
I/O types
analogue input (thermocouple, RTD, voltage, current), analogue output, digital I/O, relay output, multifunction
Example multifunction module
3 differential AI, 6 DI, 3 relay outputs
Analogue input ranges
±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, 0–20 mA, ±20 mA, 4–20 mA
Resolution
16-bit (normal mode); 12-bit (fast mode)
Sampling rate
10 samples/s (normal); 60 samples/s (fast)
Accuracy
±0.1 % (normal); ±0.5 % (fast)
Relay output current
5.0 A per channel at 25 °C
Operating temperature
−25 to 75 °C
Humidity
10 to 90 %RH, non-condensing
Mounting
DIN rail or wall
Approvals
CE, RoHS
Request a quote
Review enquiry

The OME-ET-7000 and OME-PET-7000 series are Ethernet remote I/O modules with a built-in web server. They connect analogue and digital field signals directly to an Ethernet network, so that measured values can be acquired and outputs switched from a SCADA system, a PLC or a standard web browser. Modules are available for analogue input from thermocouples, RTDs, voltage and current, for analogue output, digital input and output, relay output and multifunction I/O.

The built-in web server allows remote configuration and monitoring and control of the I/O from a standard browser, and a web HMI can be created on the module. For integration into SCADA systems the modules support Modbus TCP and Modbus UDP. Communication security functions and a dual watchdog system are included. OME-ET models are powered through a terminal block, while OME-PET models can be powered over the network using Power over Ethernet to IEEE 802.3af, which removes the need for a separate supply cable at the module.

The listed multifunction configuration has three differential analogue inputs, six digital inputs and three relay outputs. Analogue input ranges are ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, 0–20 mA, ±20 mA and 4–20 mA. In normal mode, resolution is 16 bits, the sampling rate 10 samples per second and accuracy ±0.1 %; in fast mode, resolution is 12 bits, the sampling rate 60 samples per second and accuracy ±0.5 %. Bandwidth is 500 Hz, and relay outputs are rated 5.0 A per channel at 25 °C.

The modules operate over a wide temperature range from −25 to 75 °C and can be stored from −30 to 80 °C, at 10 to 90 %RH non-condensing. They are 35 mm high and are mounted on a DIN rail or on a wall. EMC immunity is tested to IEC 61000-4-2, -4-4 and -4-5, and the modules are CE marked and RoHS compliant.

Accessories include a DIN rail (RAIL-35-1), a DIN rail power supply (iDRN-PS-1000) and Ethernet switches with and without PoE (OM-ESW-105, OM-ESW-105-POE). Stated applications are building automation, factory automation, machine automation, remote maintenance and testing equipment.

Please list the number and type of signals to be connected, whether PoE is required and which control system will read the modules, and we will select the module types.

Part numbers · 32

OME-ET-7000, OME-PET-7000, OME-ET-7002, OME-PET-7002, OME-ET-7015, OME-PET-7015, OME-ET-7017, OME-PET-7017, OME-ET-7017-10, OME-PET-7017-10, OME-ET-7018Z, OME-PET-7018Z, OME-ET-7019Z, OME-PET-7019Z, OME-ET-7026, OME-PET-7026, OME-ET-7042, OME-PET-7042, OME-ET-7044, OME-PET-7044, OME-ET-7050, OME-PET-7050, OME-ET-7051, OME-PET-7051, OME-ET-7052, OME-PET-7052, OME-ET-7053, OME-PET-7053, OME-ET-7060, OME-PET-7060, OME-ET-7067, OME-PET-7067

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.