UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Signal conditioners & barriers
The P30O is a programmable transducer for pulse-type signals. It converts inputs such as pulses, frequency, revolutions and operating time into digital or standard current and voltage signals, as described by the manufacturer, and makes the results available over Ethernet and Modbus. It is a compact unit measuring 45 × 120 × 100 mm.
The device has two universal pulse inputs. A mathematical function can be applied to each input, and each input can be given an individual characteristic with up to 21 points, so non-linear relationships between the pulse signal and the required process value can be reproduced. In this way the inputs can deliver counts, frequency, revolutions or operating time as the required process value.
One or two alarm outputs are available as options and switch when programmed limit values are exceeded. An optional 24 V DC supply can feed the connected field transmitters, so a separate power supply for sensors is not needed.
Measured data can be recorded. The internal memory holds up to 4 MB; as options, an SD/SDHC card slot or an 8 GB internal file system are available for longer recording. Three basic versions are listed: standard, with Ethernet and internal memory, and with an SD card.
For communication, the transducer has an RS-485 interface with Modbus RTU slave protocol and, optionally, Modbus TCP slave over Ethernet. Configuration can be done with the front buttons, over RS-485, with the configuration software or through the built-in web server. The firmware can be upgraded by the user.
The P30O is supplied with an EU Declaration of Conformity.
Thanks to the combination of pulse inputs, alarm outputs, data memory and Modbus interfaces, one unit both processes the signals locally and makes them available to supervisory systems over the network.
To order the right version, please state the input signals, whether alarm outputs, sensor supply, Ethernet with Modbus TCP and SD card or internal file system memory are required.
P30O
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.