PACE6000-ADC is a twin-channel pressure control system for the precision calibration and verification of aircraft pitot-static instruments. One channel generates and controls static pressure (Ps), the other pitot pressure (Pt), so the two pressures that an aircraft's air data system receives from its static ports and pitot tubes can be simulated together under controlled conditions.
With these controlled pressure outputs the system tests flight instrumentation such as altimeters, airspeed indicators, rate of climb indicators, Mach meters and air data computers. Altitude corresponds to the static pressure, while airspeed and Mach number are derived from the relationship between pitot and static pressure; controlling both channels therefore allows each of these instruments to be checked at defined test points. The system is compliant with RVSM (reduced vertical separation minimum) requirements.
The controller is fully programmable for fixed wing and rotary wing aircraft, so test sequences can be set up for the type being serviced. For integration into automatic test equipment (ATE), it is fitted with IEEE 488 interfaces, through which a host system can command set points and read results.
Mechanically, the instrument is designed for 483 mm (19 in) rack mounting and has a height of 132 mm (5.2 in), corresponding to three rack units (3U). The pneumatic supplies required for the pressure and vacuum ranges are provided by a separate pressure/vacuum supply unit, PV 103.
Two versions are listed: PACE6000-ADC and PACE6000 E-ADC. Stated fields of use are aerospace, defence and space, flight and ground test, maintenance, repair and overhaul (MRO) and test, and metrology and calibration laboratories. In each of these the system serves as the pressure reference for the pitot-static and air data instruments named above.
Please send the version required, the instruments to be tested, whether the PV 103 supply unit is needed and details of any ATE system to which the calibrator will be connected.
PACE6000-ADC, PACE6000 E-ADC, PV 103
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.