SA502-3G is a measuring transducer for maritime automation systems that converts potentiometer signals into standardised analogue and digital output signals. It is used where a position is taken from a potentiometer, such as blade pitch detection on controllable-pitch (CPP) propellers or rudder angle display, and must be passed on to indicators or the automation system as a standard signal.
The transducer supplies the potentiometer with a 15 V feed and evaluates the wiper voltage to determine the position. The relationship between position and output can be adjusted flexibly by linearisation using three adjustable base points, so the output follows the actual mechanical position even if the potentiometer movement is not linear. Inputs of ±10 V DC and a dry contact (normally open) are also listed.
Two galvanically isolated analogue outputs are available at the same time: one 0–10 V DC and one 0–20 mA. All potentiometer lines are monitored for wire break; a fault is shown by an LED and signalled by a relay output, so a broken connection does not go unnoticed as a false position value.
The device runs on 18 to 32 V DC with an idle current consumption of less than 75 mA. Operating temperature is −25 to +55 °C, storage temperature −40 to +85 °C, and vibration resistance is up to 4 g. The compact PVC enclosure is IP20, measures 22.6 × 65.8 × 102 mm and snaps onto a 35 mm DIN rail.
The transducer holds class approvals from ABS, BV, DNV, KR and LR and is CE marked. It is tested for dry heat, cold, damp heat and vibration to IEC 60068-2, degree of protection to DIN EN 60529 and EMC to IEC 61000-6-4 and CISPR 16. The signal characteristic can be adjusted to the application.
Stated fields of use are variable-pitch propeller systems, CPP propellers, rudder angle display and marine automation systems. Please describe the potentiometer, the required output signal and the classification society approval needed for your vessel.
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.