Type 3365 is an electromotive 2-way tank bottom diaphragm valve. Instead of a pneumatic actuator it uses an electrically controlled linear actuator with an integrated positioner, so the valve can be positioned precisely and controlled directly by an electrical signal or a fieldbus. The tank bottom design allows the valve to be installed at the bottom outlet of a vessel, and the diaphragm separates the medium from the actuator.
The actuator moves the diaphragm by means of a ball screw and reaches the desired position at a travel speed of up to 4 mm/s. A 360° LED ring indicates the valve position and status at a glance. As an option, an energy storage device (SAFEPOS) moves the valve into a defined safety position if the supply voltage fails.
The valve is available in nominal diameters from DN 06 to DN 100. It operates on 24 V DC and is rated for medium temperatures from −10 to +143 °C and ambient temperatures from −10 to +65 °C. Set-points can be given as 4–20 mA or 0…5/10 V analogue signals, through a binary input or digitally via büS; the electrical connection is made with two M12 circular plugs. Through gateways the valve can be integrated into CANopen, Modbus TCP, PROFINET, EtherNet/IP and EtherCAT networks, and an optional process controller can be integrated.
The body is made of stainless steel 1.4435 (316L), with welded or clamp connections to the relevant tube and fitting standards, including DIN 11866 series A, B and C, DIN 11850 series 2, DIN EN 10357 series A, ISO 4200 and DIN 32676 series A. Wetted surfaces are available with roughness from Ra ≤ 0.38 µm to 1.6 µm. Diaphragms can be chosen in EPDM, PTFE/EPDM, Advanced PTFE/EPDM and other combinations. The degree of protection is IP65/IP67, and the explosion-protected version is marked II 3G Ex ec IIC T4 Gc and II 3D Ex tc IIIC T135 °C Dc for zones 2 and 22. The valve holds 3-A and ATEX approvals.
Options include the SAFEPOS energy storage device, a process controller, an industrial Ethernet gateway and a fieldbus gateway.
The valve is intended for hygienic applications and aggressive ambient conditions, and for neutral gases and liquids, highly purified, sterile, aggressive or abrasive media. Please send the nominal diameter, connection type, diaphragm material, surface finish and required communication with your enquiry.
Type 3365
Record the valve tag, travel, pressure drop and actuator supply. Specify the required fail position and the existing feedback interface.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.