UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Signal conditioners & barriers
The VFG5 is a measuring transducer that converts sinusoidal frequency signals into a standardised current output of 0–20 mA or 4–20 mA. It is a compact and robust DIN-rail device designed for harsh environments and marine applications and holds DNV and LR certificates.
The transducer receives the sinusoidal frequency signal at its input and delivers an output current proportional to the frequency. The sensor input and the supply voltage are galvanically isolated from each other. The measuring range can be fine-adjusted with a sealed integrated trimming potentiometer, and an integrated LED indicates the operating status.
Input ranges such as 10–100 Hz, 20–1,000 Hz and 200–10,000 Hz are listed. The output is either 0–20 mA (version -I1) or 4–20 mA (version -I2), with a permissible load resistance of 0 to 500 Ω. The 4–20 mA version has a live zero, so a signal of 0 mA can be distinguished from the lower end of the measuring range. An example part number is VFG501-I2-352, which designates a specific combination of input range and 4–20 mA output. Related versions of the product family with short-circuit-proof voltage outputs of 0–10 V DC and 2–10 V DC are also mentioned in the data.
The transducer is supplied with 9 to 32 V DC and operates at ambient temperatures from −20 °C to +70 °C. Electrical connections are gold-plated tab connectors A6.3 × 0.8 according to DIN EN 46244. The device snaps onto a TS32 G-rail or a TS35 top-hat rail. A declaration of conformity for the Vx5 family is available.
Listed fields of use are marine applications and harsh environments.
When requesting a quotation, please state the input frequency range, the output signal (0–20 mA or 4–20 mA) and the quantity required.
VFG501-I2-352
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.