UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Process & PID controllers
The 1161+ is a fail-safe limit controller in 1/16 DIN format from the P Series family. It provides dependable limit protection for industrial and process control systems, acting as an independent safeguard that switches the process off when a limit is reached.
The controller has a latched limit relay that operates when the process value exceeds, or falls below, a predefined limit. The relay then shuts the process down and remains latched until the controller is reset, so the process cannot restart on its own once the value has returned within limits. Clear LED status indicators show when the limit has been reached and when the relay is still latched. A 5 A latching limit relay is fitted as standard.
In addition to the limit function, the controller provides process alarms for enhanced system protection. Further output positions can be configured with a relay, an SSR driver (a 10 V SSR driver output is optional), a DC SSR driver, a linear DC output with 4–20 mA as default, or a transmitter power supply, or can be left unfitted. An optional digital input allows remote reset. Optional RS-485 serial communication with Modbus allows the controller to be connected to a supervisory system.
Operation is via an easy-to-use HMI with a customisable operator menu, and the controller can also be configured from a PC. Auto-hardware detection and jumperless configuration simplify setup when option modules are fitted.
The unit is available for a supply voltage of 100–240 V AC or 24–48 V AC/DC. It is FM approved. Panel cutout, housing and terminal wiring are backward-compatible, so the 1161+ can replace earlier units in existing panels without rework.
Configured versions are ordered under codes beginning with P1161, for example P1161100000, P1161110000, P1161111000 or P1161113800, where the digits define the supply voltage and the fitted outputs and options.
The listed fields of application are industrial installations and process control systems.
To prepare a quotation, please send the supply voltage, the required outputs, whether Modbus communication and the digital input are needed, or the full order code.
P1161110100, P1161113802, P1161110000, P1161100002, P1161113800, P1161110002, P1161110800, P1161111000, P1161100000, P1161110300, P1161100100, P1161113000, P1161100800, P1161111002, P1161111200, P1161114800, P1161131000, P1161103000, P1161100300, P1161103200, P1161130100, P1161111100, P1161111400, P1161113100, P1161111300
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.