PACE6000-ADC
Calibration

Temperature calibrators
The 1551A Ex and 1552A Ex are digital reference thermometers for use as a modern replacement for mercury-in-glass thermometers. They combine a stable platinum resistance probe with a battery-powered readout and are certified intrinsically safe, so they can be used directly in areas with flammable vapours, such as tank farms, terminals and process units.
Accuracy is ±0.05 °C over the full range, including the probe. The 1551A Ex with a thin-film sensor covers −50 to 160 °C; the 1552A Ex with a wire-wound sensor covers −80 to 300 °C. Resolution is selectable at 0.1, 0.01 or 0.001 degree, and the sample rate at 0.5, 1 or 2 seconds. A configurable stability and trend indicator shows when the reading has settled, which saves time and avoids premature readings during calibration.
Probes are made of stainless steel and offered in 229, 305 and 508 mm lengths with 4.8 or 6.35 mm diameter. The probe mount rotates so that the display stays readable at any angle. Each thermometer comes with an accredited, traceable calibration, and a three-point calibration function lets the user adjust it against a reference. Models with the -DL suffix log readings internally; data and calibration parameters can be transferred over RS-232, which is used outside the hazardous area only.
The device is certified to ATEX and IECEx with marking Ex ib IIB T4 Gb, in line with IEC 60079-0 and IEC 60079-11. Battery life is up to 300 hours, with automatic switch-off; batteries are replaced outside the hazardous area. The readout operates from −10 to 50 °C and up to 95 %RH non-condensing.
Typical applications are custody transfer temperature measurement of petroleum products, daily checks of working thermometers, calibration and verification of temperature transmitters, RTDs and thermocouples, calibration of liquid-in-glass and electronic thermometers, and single-point verification of process measurements. Please indicate range, probe length and whether data logging is required.
1552A-12, 1552A-12-DL, 1551A Ex, 1552A Ex, 1551A-9, 1551A-12, 1551A-20, 1552A
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.