PACE6000-ADC
Calibration

Temperature calibrators
The 1595A Super-Thermometer is a high-precision digital thermometer readout for primary standards laboratories and temperature calibration. It performs high-accuracy resistance ratio and absolute resistance measurements and works with standard platinum resistance thermometers (SPRTs), PRTs, RTDs and thermistors, reaching an accuracy as good as 0.06 ppm, equivalent to 0.000015 °C.
The instrument measures 4-wire PRTs, thermistors, resistance and resistance ratio. The unknown resistance is compared with internal, temperature-controlled reference resistors of 1 Ω, 10 Ω, 25 Ω, 100 Ω and 10 kΩ, or with an external reference resistor from 1 Ω to 10 kΩ connected to one of the two dedicated rear-panel inputs. The input resistance range is 0 to 500 kΩ and the ratio range 0 to 10. A ratio self-calibration function verifies the accuracy of the resistance ratio, and zero-power measurement eliminates self-heating errors of the sensor.
PRT readings can be converted with ITS-90, PT-100, CVD-ABC, CVD-ALPHA or polynomial equations, and thermistor readings with R(T) or T(R) polynomials. Results are displayed as ratio RX/RS, in K, °C, °F or Ω, with a display resolution selectable from 0.1 to 0.000001. Sample periods of 1, 2, 5 and 10 seconds are available. Built-in statistics show average, standard deviation, standard error of the mean, maximum, minimum, difference, peak-to-peak, delta and number of samples.
The front panel has four PRT/thermistor inputs with DWF connectors and tellurium copper terminals; channels 2 and 4 can also be configured as reference inputs. Several channels can be viewed simultaneously on the full VGA LCD. Up to 80,000 time- and date-stamped readings (about 6 MB) are logged to internal memory with an internal real-time clock. For computer communication RS-232, USB, IEEE-488 and Ethernet are provided; Ethernet also allows remote viewing and control. The user interface is available in English, French, Spanish, German, Russian, Chinese and Japanese.
The instrument is rack-mountable, measures 432 × 153 × 432 mm and weighs 7.5 kg. It is powered with 100–230 V AC ±10 % at 50/60 Hz. Specifications apply from 15 to 30 °C; operation is possible from 5 to 40 °C and up to 3000 m. It complies with IEC 61010-1 (overvoltage category II, pollution degree 2) and IEC 61326-1.
Options include an NVLAP-accredited certificate of calibration, an RS-232 to USB converter cable and a regional power cord; user's and technical guides are available. Please state the sensors to be measured, the reference resistors used and whether an accredited certificate is needed in your enquiry.
CAL-1595A
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.