PACE6000-ADC
Calibration

Multifunction process calibrators
The 5560A, 5550A, 5540A and 5530A form a family of multi-product calibrators for calibration laboratories, service centres, quality departments and manufacturing test. One instrument replaces several separate sources: it generates precise DC and AC voltage, DC and AC current, resistance, capacitance, inductance and simulated temperature signals, and with the oscilloscope option it also calibrates oscilloscopes. The four models differ in specifications and options, from the basic 5530A to the high-performance 5560A.
The outputs are generated by an ultra-linear digital-to-analog design. DC voltage reaches ±1020 V and AC voltage covers 12 mV to 1020 V. Current up to 30.2 A is available continuously, and with 10-turn and 50-turn current coils clamp meters and Rogowski coils can be calibrated at effective currents up to 6000 A. Resistance from 0 Ω to 1200 MΩ, capacitance up to 120 mF and synthesised inductance from 13 µH to 120 H are variable, with four-wire compensation and external sense for low-resistance work. The top model calibrates 6.5-digit digital multimeters with a test uncertainty ratio of 4:1.
For temperature instruments the calibrators simulate 17 thermocouple types and 10 RTD types according to ITS-90 or IPTS-68. With the scope options at 600 MHz, 1.1 GHz or 2.1 GHz the instrument provides levelled sine waves, fast edges below 175 ps, time markers with 2.5 ppm accuracy and amplitudes up to 120 V for testing modern digital oscilloscopes.
The calibrators are operated through a large colour touch screen with a graphical user interface, and the dedicated output terminals reduce the risk of wrong connections. Reverse power protection guards the outputs. For automated calibration the instruments are controlled via IEEE-488 (GPIB), USB, Ethernet or RS-232 and work with common calibration management software. A DMM autocal adapter simplifies calibration of multimeters with automatic adjustment.
The instruments stand on the bench or are installed in a standard 19-inch rack with a rack-mount kit; a portability kit allows on-site and mobile calibration. Typical workloads are digital multimeters, clamp meters, Rogowski coils, LCR meters, power and process meters, temperature indicators and oscilloscopes. Please tell us which instruments you need to calibrate and the accuracy you require, and we will recommend the model and options.
5560A, 5560A/2G, 5560A/1G, 5560A/600M, 5550A, 5550A/1G, 5550A/600M, 5540A, 5540A/600M, 5530A, 5550A/6, 5560A/6, 55XXA/COIL 10, 55XXA/COIL 50, 55XXA/LEADS, 55XXA/PORTKIT, 55XXA/DMMCAL, 55XXA/CASE, Y5537, 55XX/CASE, MET/CAL/TEAM, MET/CAL-TL, MET/CAL/TEAMXP, MET/CAL-METCON, MET/CAL-MCL, MET/SUPPORT Gold, MET/SUPPORT Preferred, 690230, 601127, 5274606, 2747820, 773135, 601747, 2670161, 55X0A-4401, 5587423, 643640, 4044919, 851931, 5037050, 5128204, 5128219, 5128228, 5128237, 5128243, 5128255, LC-1, LC-2, LC-3, LC-4, LC-5, LC-6, LC-7, Y5538
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.