PACE6000-ADC
Calibration

Temperature calibrators
The 724 is a portable temperature calibrator for testing and calibrating temperature sensors and transmitters. It measures and sources twelve thermocouple types, seven RTD types, volts and ohms, so that both sensors and the instruments connected to them can be checked with one device in the plant and in the field.
A dual-line display shows input and output at the same time: one line can display the measured signal and the other the sourced value. This is used, for example, when the calibrator simulates a sensor at the input of a transmitter and measures the transmitter's output. For this purpose the 724 provides loop power to the transmitter while measuring the mA signal. Ramp and step functions support linearity tests and remote testing, and the controls are designed without menus.
DC voltage is measured in ranges of 30 V (upper display), 20 V (lower display), 100 mV and −10 to 75 mV; DC current is measured up to 24 mA. Resistance is measured from 0 to 3200 Ω in three ranges. As a source the 724 provides 100 mV, 10 V and −10 to 75 mV and simulates resistance from 15 to 3200 Ω in three ranges. The loop supply delivers 24 V with a maximum current of 22 mA.
The display is backlit for work in poor lighting. Power comes from four AA alkaline batteries, with a typical battery life of 25 hours. The calibrator operates from −10 to 55 °C, is stored from −20 to 71 °C, measures 96 × 200 × 47 mm and weighs 650 g. It withstands random vibration of 2 g from 5 to 500 Hz. Safety is to CSA C22.2 No. 1010.1, and EMC to EN 50082-1 and EN 55022; the device carries CE and CSA marking.
Accessories include AC70A test clips, TL75 test leads, stackable test leads and thermocouple mini-plug kits 700TC1 and 700TC2.
Listed applications are testing plant temperature sensors, calibrating transmitters and field troubleshooting of temperature loops. Please state which accessories are required with the calibrator in your enquiry.
724
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.