Temperature calibrators
The 9150 is a portable thermocouple furnace for low-cost, field-based calibration of thermocouples and RTD probes. It serves as a precision temperature calibration dry-well and covers temperatures from 150 °C to 1200 °C. It is also used as a temperature source for calibrating thermocouples connected to HART smart transmitters.
At the heart of the furnace is a constant temperature aluminium-oxide block, heated by surrounding heaters. A microprocessor-based controller with a type S thermocouple sensor regulates the temperature, and the heater is driven by a solid-state relay. The probe under test is inserted into the well and compared at stable temperature points.
The stated stability is ±0.5 °C and the display accuracy is ±5 °C. Well-to-well uniformity is ±2.5 °C, measured with insert C at 1200 °C. The temperature is shown with a resolution of one tenth of a degree Celsius or Fahrenheit. Heating to 1200 °C takes 35 minutes, cooling takes 140 minutes with the block, and stabilisation takes 20 minutes.
The well has a diameter of 32 mm (1.25 in) and a depth of 140 mm, made up of a 101 mm removable insert plus a 38 mm insulator. Interchangeable inserts accept probes from 1/16 in to 1/2 in diameter. A standard RS-232 port allows connection to a PC.
The furnace operates on switchable 115 V AC (10.5 A) or 230 V AC (5.2 A), 50/60 Hz, with a power of 1200 W; fuses are 12 A for 115 V and 6.3 A for 230 V. It measures 315 × 208 × 315 mm and weighs 13 kg. Conformity with EMC and low voltage directives and IEC 1010-1 is stated. A NIST-traceable calibration is included.
Accessories include inserts 9150-A, 9150-B, 9150-C and 9150-D (also listed as 3150-2, 3150-3, 3150-4 and 3150-6), multi-hole probe sleeves, an insulator sleeve, tongs and the 9315 carrying case.
Typical uses are calibration of thermocouples and RTD probes in process manufacturing, laboratory calibration and field maintenance. Please send the diameters and types of probes you need to calibrate, and the required supply voltage, with your enquiry.
9150-X, 3150-2, 3150-3, 3150-4, 3150-6, 9315
Identify the instrument under test and the points to reproduce. State the required uncertainty, reference conditions and certificate format.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.