UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Process & PID controllers
The ALC-4 is an automatic load controller for critical power installations and power plants. It integrates load handling into a power management system and works together with other controllers of the same family, such as AGC-4, AGC 150 and ASC-4, to manage groups of consumers.
The controller receives power data from the power management system and controls up to eight load group breakers, that is, consumer feeders. Consumers are prioritised: during a power shortage the least important feeders are disconnected, and when power becomes available again they are reconnected. This optimises the use of the available power and, as stated, helps reduce fuel costs. A Heavy Consumer (HC) function is supported, and the unit can run in AUTO or SEMI operating mode.
Measurement accuracy is class 1.0. The measuring voltage range is 100 to 690 V AC ±20 % and the measuring frequency range is 30 to 70 Hz. The auxiliary supply is 8 to 36 V DC.
As standard, the controller has five relay outputs and seven binary inputs. Further I/O is added with option modules in slots 2 to 8, for example M13 modules with seven binary or digital inputs, M14 modules with four relay outputs, M12 with thirteen digital inputs and four relay outputs, and M15 with four 4–20 mA inputs. Communication options include Modbus RTU over RS-485 (option H2), Modbus TCP over Ethernet, CANbus and USB.
The unit is mounted on a DIN rail or on a base with six M4 screws; the stated tightening torque is 1.5 Nm for screws, 0.5 Nm for plug connections and 0.2 Nm for the Sub-D screw. The unit is rated IP20 and the display IP40, or IP54 with the gasket of option L. It operates from −25 to 70 °C and can be stored from −40 to 70 °C. The device carries cULus, TÜV and VDE approvals and lists VDE AR-N 4110, VDE AR-N 4105, EN 50549-1:2019, ENA EREC G99, IEC 61010-1, UL 508 and EN 61000-6-2/-6-4.
Applications named for the controller include power generation, genset OEM systems, power and energy management, hybrid and microgrid systems and off-grid power management. Please send the number of load groups, the required I/O and the communication interface with your enquiry.
ALC-4
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.