Brüel & Kjær Vibro ASA-063
Brüel & Kjær Vibro

ASA-063 explosion-protected CCS acceleration sensor, 100 mV/g

Vibration & condition monitoring

Manufacturer
Brüel & Kjær Vibro
Model
ASA-063
Instrument type
Vibration & condition monitoring
Type
CCS (constant current supply), piezoelectric compression
Sensitivity
100 mV/g
Frequency range
1.5 Hz … 13 kHz
Temperature range
−55 to +125 °C
ATEX marking
II 1 G Ex ia IIC T6…T1 Ga; II 2 G Ex ia IIC T6…T1 Gb; II 2 D Ex ia IIIC T85 °C…T145 °C Db
IECEx marking
Ex ia IIC T6…T1 Ga / Gb; Ex ia IIIC T85 °C…T145 °C Db
Entity parameters
Ui 28 V; Ii 95 mA; Pi 665 mW; Li negligible
Resting potential
+12.5 V
Dynamic output impedance
≤ 300 Ω
Insulation resistance
≥ 20 MΩ
Connector
MIL C-5015 5/8" – 24 UNEF 2A (A: +SIG, B: 0 V/GND)
Mounting
M8 or 1/4" 28 UNF threaded stud
Body material
stainless steel 1.4301
Protection
IP66/67
Weight
approx. 130 g
Request a quote
Review enquiry

The ASA-063 is an explosion-protected acceleration sensor with constant current supply (CCS). It is designed for measuring mechanical vibration on rotating machinery such as turbines, pumps and compressors installed in potentially explosive atmospheres with gas or dust, indoors and outdoors.

The sensor works on the piezoelectric compression principle. A piezo-ceramic disc and an internal seismic mass form a spring-mass-damping system. When the machine vibrates, the mass exerts an alternating force on the ceramic disc, which generates an electrical charge proportional to acceleration. An integrated amplifier converts this charge into a voltage signal.

Sensitivity is 100 mV/g and the frequency range 1.5 Hz to 13 kHz. The sensor operates from −55 °C to +125 °C. Its resting potential is +12.5 V, the maximum output voltage +30 V, the dynamic output impedance at most 300 Ω and the insulation resistance at least 20 MΩ. It can be used up to 2000 m altitude, at up to 99 % relative humidity and in pollution degree 3; EMC complies with EN IEC 61326-1.

The sensor is intrinsically safe and certified under ATEX and IECEx. The ATEX marking is II 1 G Ex ia IIC T6…T1 Ga, II 2 G Ex ia IIC T6…T1 Gb and II 2 D Ex ia IIIC T85 °C…T145 °C Db; the IECEx marking is the equivalent Ex ia IIC T6…T1 Ga/Gb and Ex ia IIIC T85 °C…T145 °C Db. The input parameters for the intrinsically safe circuit are Ui = 28 V, Ii = 95 mA and Pi = 665 mW, with negligible inductance. Further approvals include CE and CCC, conformity to TP TC 012/2011 and GB/T 3836 is stated, and the product complies with REACH. Reference standards are EN IEC 60079-0 and EN 60079-11; installation follows EN 60079-14.

The body is made of 1.4301 stainless steel, rated IP66/67, and weighs about 130 g. The electrical connection is a MIL C-5015 5/8" – 24 UNEF 2A plug, with pin A for the signal and supply (+) and pin B for 0 V/GND. The sensor is mounted on an M8 or 1/4" 28 UNF threaded stud with a tightening torque of 3.5 Nm, or 6.5 Nm for M8 × 14.

Accessories include connecting cables EL2075-S, EL2157-S and AC-1607, mounting bolt AC-352, threaded bolts AC-3362 and AC-3360, sensor mounting plate AC-274, mounting magnets AC-172 and AC-273 and voltage repeater EQ2425. Installation must be carried out by qualified electricians or trained personnel. Please state the hazardous area classification, mounting method and required cable length in your enquiry.

Part numbers · 13

ASA-063, AC-1607, AC-352, AC-3362, AC-3360, AC-274, AC-172, AC-273, EQ2425, AC-297, AC-1114, AC-1141, EQ2425/AC-4299

Industry applications

Selection notes

Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.