DEIF A/S BQ
DEIF A/S

BQ bimetallic maximum demand ammeter

Indicators & totalisers

Manufacturer
DEIF A/S
Model
BQ
Instrument type
Indicators & totalisers
Measuring principle
bimetallic, ambient temperature compensated
Measuring range
0–6 A or 0–1.2 A (for /5 A or /1 A CT)
Accuracy class
3.0
Setting time
BQ48: 4 or 8 min; BQ72/BQ96: 8 or 15 min
Scale
120 % of CT primary current, exchangeable
Scale end values
6-12-18-24-30-36-48-60-72-90-96 and multiples of 10
Burden
approx. 1.2 VA (1 A); approx. 2.2 VA (5 A)
Overload
1.2 × In continuous; 10 × In for 1 s
Operating temperature
−25 to 60 °C (nominal −10 to 55 °C)
Storage temperature
−25 to 65 °C
Protection
IP52
Mounting
DIN rail
Approvals
CE, DNV
Request a quote
Review enquiry

The BQ series are bimetallic maximum demand ammeters for the thermal control of cables and transformers. Instead of showing the instantaneous current, they indicate the thermal effect of the load over a defined time, which corresponds to the heating of the monitored cable or transformer, and they record the highest value reached with a separate maximum pointer.

The measuring system consists of two mechanically connected bimetallic spiral springs. One is heated by the measuring current and expands, driving the pointer over a quadratic scale; the other compensates for changes in ambient temperature. Because of the inertia of the system, brief current pulses do not affect the reading. A red maximum-reading pointer is carried along by the measuring pointer and remains at the peak value until it is reset with a knob.

The meters are connected directly to a current transformer with a 1 A or 5 A secondary, giving measuring ranges of 0 to 1.2 A or 0 to 6 A. The scale always corresponds to 120 % of the transformer rating and can be exchanged; standard end values are 6, 12, 18, 24, 30, 36, 48, 60, 72, 90 and 96 and multiples of 10. Accuracy class is 3.0 to EN 60051. The setting time is 4 or 8 minutes for the BQ48 and 8 or 15 minutes for the BQ72 and BQ96. The burden is approximately 1.2 VA at 1 A and 2.2 VA at 5 A; the meter withstands 1.2 times nominal current continuously and 10 times nominal current for one second.

The nominal temperature range is −10 to 55 °C, the operating range −25 to 60 °C and storage −25 to 65 °C. Protection is IP52 to EN 60529, and the meters are designed for DIN rail mounting. They carry the CE mark and a DNV approval, and refer to EN 50081 and EN 50082 for EMC.

Applications named are thermal control of cables and transformers and marine and offshore switchboards. Please state the size, CT ratio, scale end value and setting time in your enquiry.

Part numbers · 3

2961210420, 2961210720, 2961210920

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.