UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Process & PID controllers
The C300 is a controller for the Experion PKS distributed control system. It is delivered secure out of the box with embedded cybersecurity, which supports compliance, reduces risks and improves availability. The controller is used for continuous and batch processes in power generation, oil and gas onshore and offshore, subsea production systems, mining and process manufacturing.
The C300 runs the deterministic Control Execution Environment (CEE). The CEE executes control strategies on a constant and predictable schedule, with a standard execution period of 50 ms, and integrates standard and open communication protocols transparently. It supports advanced process control and custom algorithm blocks for user-defined code. Capacity figures are 32,768 memory units of battery-backed user memory, up to 4095 tagged blocks and 9000 execution units; with Control HIVE deployment, 1500 I/O HIVE parameter references are available.
High availability is achieved by redundant deployment. Primary and secondary controllers synchronise automatically, synchronisation takes about 240 s, and in case of failure the controller performs a bumpless failover to the healthy partner within about 500 ms. Traditional 1:1 redundancy uses a dedicated IOTA and redundancy cable. Warm and cold restart are supported, and the CC-SCMB05 module provides power-loss recovery.
Communication is based on Fault Tolerant Ethernet (FTE), which also shields the controller against network attacks, together with a control firewall. Time is synchronised by SNTP every minute or by PTP to IEEE 1588 every 30 seconds. The controller connects to Series C I/O and Process Manager I/O families via dedicated redundant networks and integrates smart field devices via EtherNet/IP, PROFINET, Foundation Fieldbus, HART and IEC 61850. It natively supports the FMC722 subsea protocol. Embedded security is certified to ISASecure CSA Level 2.
The controller has the Series C form factor and is mounted vertically on its I/O termination assembly (IOTA); the vertical design improves wire entry and heat flow. It operates from −40 to +70 °C and carries CSA approval. Batch control follows ISA S88.01.
Please send the controller part number (for example PCNT05), the required redundancy configuration and the I/O families to be connected with your enquiry.
PCNT05, CC-SCMB05, C300
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.