Mechanical & physical measurement

Torque sensors
The DFG-RS5 is a universal digital indicator for remote force and torque sensors. It is the readout unit for a range of interchangeable load cells and reaction torque sensors, which are ordered separately, and is used handheld, mounted on fixtures or integrated into test stands.
The key feature is true interchangeability. Calibration and configuration data are stored in a smart connector on each sensor. When a sensor is plugged in, the indicator reads this data automatically, so the user can switch between, for example, a small tension and compression load cell, a heavy-duty compression cell and a torque sensor without recalibration or manual setup. This lets one indicator serve many test tasks.
The indicator samples at 7000 Hz, which allows short force peaks to be captured reliably. Accuracy is ±0.1 %, and the system accuracy is 0.1 to 0.25 % depending on the sensor. Units of measure are selectable. A large backlit graphic LCD shows the current value, peaks and status. Up to 1000 readings can be stored on board and recalled or transferred later.
For data acquisition and automation the DFG-RS5 has USB and RS-232 interfaces at 115,200 baud, a ±1 V DC analogue output, three open-drain outputs for configurable set points and a Digimatic serial BCD output. Power comes from an AC adaptor or an internal NiMH battery. The unit measures about 149 × 64 × 34 mm, weighs 0.32 kg and operates from 5 to 38 °C.
Matching sensors include tension and compression load cells from ±0.25 lb to ±10,000 lb, compression load cells up to 10,000 lb, miniature cells and reaction torque sensors from ±10 oz-in to ±100 lb-in. A configurable adaptor (DFG-RSA) allows other sensors to be connected. The indicator is CE and UKCA marked and RoHS compliant. Please tell us the forces or torques you need to measure, and we will propose an indicator with suitable sensors.
DFG-RS5, DFG-RSA
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.