DP119 is an economical miniature panel thermometer for direct-reading temperature monitoring in industrial process control. It accepts a thermocouple or a 100 Ω platinum RTD directly, without a separate transmitter, and displays the temperature on a 3½-digit LED display with 14.2 mm digits. The 1/8 DIN housing fits a standard 45 × 92 mm panel cut-out.
The meter processes the signal from thermocouple types J, K, T or E, or from a 100 Ω platinum RTD, linearises it and shows the result in °C or °F. Depending on model, the resolution is 1 degree or 0.1 degree. The reading rate is 2.5 readings per second with a step response of 1 second, and a display hold function freezes the reading when required.
Stated accuracy is ±1.5 °C + 1 count for thermocouple models with 1-degree resolution and ±1 °C + 1 count for thermocouple models with 0.1-degree resolution; for RTD models a figure of ±0.3 °C is given. In addition to the display, the meter provides a standard linearised analogue output of 1 mV or 10 mV per degree, depending on resolution, which can drive a recorder or another instrument.
The standard power supply is 115 V AC; 230 V AC (suffix -230) and a non-isolated 9 to 32 V DC supply (suffix -9/26) are available as options. Power consumption is 2 W. The display is red as standard and green with the suffix -GR.
The front is sealed to IP65 and NEMA Type 4. The housing measures 96 × 48 mm at the front and 120 mm in depth, and the meter weighs 225 g. Operating temperature is 0 to 60 °C. The instrument is RoHS 2 compliant and is supplied with an operator's manual. Model codes such as DP119-JC1, DP119-KC2 or DP119-KF1 identify the input type and resolution.
Please state the sensor type, the required resolution and display unit, the supply voltage and the display colour, and we will confirm the model code.
DP119-JC1, DP119-JC2, DP119-JF1, DP119-JF2, DP119-KC1, DP119-KC2, DP119-KF1, DP119-KF2, DP119-TC1, DP119-TC2, DP119-TF1, DP119-TF2, DP119-EC1, DP119-EC2, DP119-EF1, DP119-EF2, DP119-MC1, DP119-MC2, DP119-MF1, DP119-MF2
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.