UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Indicators & totalisers
The DPT35-series is a dual pulse timer and totaliser in a wall-mounted NEMA 4 enclosure. It works as a single or dual timer for meters and flow sensors that produce pulse signals and is commonly used to start timed actions in proportion to the volume of water that has passed, for example in water treatment and chemical dosing.
The device accepts the pulse input from a meter or flow sensor and counts the pulses in independent accumulators at a sampling rate of 1 kHz, that is, 1000 updates per second. When the preset number of pulses is reached, the corresponding output relay is energised for the set time. The accumulator range is 1 to 9999 pulses and the timer range 1 to 9999 seconds.
In sequential mode the two timers do not operate at the same time. This is used where two functions must not overlap, such as chemical feed and water bleed in a cooling or boiler circuit: one action follows the other after each counted batch.
Values are shown on a 6-digit, 7-segment red LED display, and settings and counts are held in non-volatile memory. The output contacts are rated 5 A at 115 V AC or 1/4 HP. The unit is supplied from 115 V AC and provides 12 V DC to power the connected sensor or transmitter. Operating temperature is 0 to 55 °C.
The enclosure is made of polycarbonate and rated NEMA 4. It is fixed to a wall with screws; meters with pulse signals are connected via a terminal block or via factory-ordered connectors. The series is RoHS compliant. Two variants are available, the standard DPT35 and the DPT35S alternate configuration.
Applications named for the series are water treatment, chemical dosing, cooling towers and boilers. Please describe the pulse source, the actions to be timed and the preferred connection method in your enquiry, so that the correct variant can be offered.
DPT35, DPT35S
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.