VVB3
Mechanical & physical measurement

Position sensors & encoders
The DWA is a potentiometric rotary position sensor for precise angular measurement. It is mechanically connected to the shaft being monitored by a pin coupling and provides an ohmic output signal that corresponds to the rotation angle. The sensor is used in shipbuilding to measure rudder or propeller pitch position.
The sensor works on the ohmic principle and has two independent signal outputs, each 0 to 2 kΩ. The shaft can rotate through 360° without a mechanical limit. No reference run is needed after switching on, and reference positions can easily be adjusted mechanically.
The measuring range is selectable from 10° to 320° in 10° steps, so that the full output span can be matched to the actual travel of the rudder or pitch mechanism. Customised rotation angles are available as -P types. The supply voltage is 15 to 30 V DC, and the operating temperature range is −40 to +70 °C.
Two mechanical designs are offered. Design -1 has a diameter of 80 mm, terminals for the electrical connection and a 40 mm pin. Design -2 has a diameter of 60 mm, a cable connection and a 30 mm pin. The standard degree of protection is IP66, and IP68 is available on request. Protection is specified with reference to DIN VDE 0470.
The DWA carries class approvals for shipbuilding from ABS, BV and DNV, the classification societies named for the sensor, which supports its use on classed vessels. Articles include DWA90-1 and the customised DWA-P versions.
Applications named are shipbuilding, rudder position monitoring and pitch position monitoring. Please state the required measuring range, the design (-1 or -2), the protection class and, if needed, any customised rotation angle in your enquiry, so that the sensor can be supplied ready for installation.
DWA90-1, DWA-P
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.