Heinrichs Messtechnik ES
Heinrichs Messtechnik

ES electronic transmitter for variable area flow meters

Variable area flowmeters

Manufacturer
Heinrichs Messtechnik
Model
ES
Instrument type
Variable area flowmeters
Function
converts float position of VA flow meter into electronic signals
Analogue output
4–20 mA, passive, galvanically isolated, HART
Accuracy
±0.2 %
Binary outputs 1 and 2
NAMUR switches, Ui = 30 V, Ii = 20 mA, Pi = 100 mW
Binary input
counter reset (versions with counter module)
Power supply
14 to 30 V DC
Ambient temperature
−40 to +70 °C
Versions
ES; ES-PPA with pulse output; ES-FF with FF protocol; ES-ZM with counter module; ES Ex
Ex approvals
ATEX (DMT 00 ATEX E 075), IECEx (BVS 16.0072), NEPSI
Other approvals
KTL; CE, EMC directive
Functions
temperature compensation, diagnostics
Request a quote
Review enquiry

The ES series is an electronic transmitter for variable area flow meters. It is mounted on a compatible meter and converts the mechanical flow indication, the position of the float, into standard electronic signals for process control, so that a local mechanical meter can also be used for remote monitoring, data logging and automatic control.

In a variable area flow meter the float settles at a height that corresponds to the flow rate. The ES transmitter detects the position of the float with a high-precision sensor, processes this position and outputs it as a 4–20 mA signal with HART communication. Temperature compensation and diagnostic functions are integrated. Stated accuracy is ±0.2 %.

The analogue output is passive and galvanically isolated; the power supply range is 14 to 30 V DC. Two binary outputs in NAMUR switch design (Ui = 30 V, Ii = 20 mA, Pi = 100 mW) are available for limit signalling. On versions with a counter module, a binary input resets the counter. The transmitter operates at ambient temperatures from −40 °C to +70 °C.

Several versions are listed: the standard ES transmitter; ES-PPA with an additional pulse output; ES-FF with the FF fieldbus protocol; ES-ZM with a counter module for totalising; and ES Ex, the explosion-proof version for hazardous areas. Configurations can be customised.

The explosion-protected design is covered by the EC-type examination certificate DMT 00 ATEX E 075 under the Explosion Protection Directive 2014/34/EU, an IECEx certificate (BVS 16.0072) and NEPSI certification; a KTL certificate is also part of the documentation. The transmitter carries the CE mark and complies with the EMC directive. The design is described as robust for harsh environments and low in maintenance, and installation and calibration on compatible flow meters are straightforward.

Listed applications are process monitoring, data logging, automated control systems, remote monitoring and hazardous environments with the explosion-proof versions.

When enquiring, please state the type of variable area flow meter on which the transmitter will be mounted, the required outputs and protocol, and whether an explosion-proof version is needed.

Part numbers · 10

ES_BA_21.01_en, ES FF – EN, ES PPA – EN, ES ZM – EN, ES Ex – EN, ES_DMT00ATEXE075_S2_en, ES_IECEx_BVS16-0072, ES_NEPSI-GYJ17.1173_en_ch, ES_KTL_19-KA4BO-0315, es_ppa_profibus_bestaetigung

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.