Surent G480
Flow

Ultrasonic flowmeters
The FDT500 series is a battery and DC powered flange-mount ultrasonic flowmeter for water service. It uses transit time technology to measure flow rate and total volume, and it has no moving parts, which keeps the pressure loss minimal.
The meter transmits and receives ultrasonic signals alternately between two flow sensors. A signal travelling with the flow arrives sooner than a signal travelling against it, and the difference in time of flight determines the flow rate. The volume is totalised and shown on the display.
Accuracy is ±2 % of reading; below the minimum transition flow rate it is ±5 %. The maximum pressure is 230 psi. The process temperature range is 0 to 50 °C for the integral display version and 0 to 90 °C for the remote display version. Each meter is supplied with a NIST three-point calibration; four-point (-NIST4) and eight-point (-NIST8) calibrations are available as options.
The 4–20 mA current output is standard. Options include an analogue output (-A), a pulse/open collector output, communications (-OPT) and a pressure output (-PS). Readings are shown on a seven-segment, eight-digit, single-line LCD.
The flow body is made of cast iron, with ABS and aluminium alloy also used in the construction, and the enclosure is rated IP68. Installation is aided by 150 lb ANSI flanges in sizes from 2 to 8 in, or DIN flanges from DN 32 to DN 200. CE and RoHS conformity is stated.
Models FDT503 to FDT509 have an integral display and FDT503-R to FDT509-R a remote display. DIN flange versions are designated FDT501-DIN to FDT509-DIN, and remote DIN versions FDT501-R-DIN to FDT509-R-DIN.
Applications named for the meter are commercial water measurement, consumable water measurement, water consumption monitoring and system leakage monitoring. When you send an enquiry, please state the pipe size and flange standard, the flow range, the water temperature, the power supply, the required outputs and whether an integral or remote display is needed.
FDT503, FDT504, FDT505, FDT506, FDT507, FDT508, FDT509, FDT503-R, FDT504-R, FDT505-R, FDT506-R, FDT507-R, FDT508-R, FDT509-R, FDT501-DIN, FDT502-DIN, FDT503-DIN, FDT504-DIN, FDT505-DIN, FDT506-DIN, FDT507-DIN, FDT508-DIN, FDT509-DIN, FDT501-R-DIN, FDT502-R-DIN, FDT503-R-DIN, FDT504-R-DIN, FDT505-R-DIN, FDT506-R-DIN, FDT507-R-DIN, FDT508-R-DIN, FDT509-R-DIN, FDT500-BAT
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.