DwyerOmega FMG90B
DwyerOmega

FMG90B compact electromagnetic flow sensor for conductive liquids

Electromagnetic flowmeters

Manufacturer
DwyerOmega
Model
FMG90B
Instrument type
Electromagnetic flowmeters
Measuring principle
magnetic induction (Faraday's law)
Media
water and other conductive liquids, above 20 µS/cm
Accuracy
±0.7 % of reading ±0.3 % of range
Repeatability
±1 %
Response time
less than 100 ms
Outputs
frequency (push-pull, NPN or PNP open collector); analogue 0.5–10 V
Supply voltage
12 to 24 V DC; max. 3.6 W
Max. operating pressure
145 psi (10 bar)
Process temperature
14 to 140 °F (−10 to 60 °C)
Operating temperature
41 to 140 °F (5 to 60 °C)
Inner diameters
0.12 to 0.98 in
Wetted materials
PVDF, 316L stainless steel, POM, EPDM, FKM; PTFE lining option
Process connections
3/8" to 1¼" NPT; BSP
Electrical connection
M12 4-pin; 10 m cable
Protection
IP65
Request a quote
Review enquiry

The FMG90B series is a compact, lightweight electromagnetic flow sensor for measuring water and other electrically conductive liquids. It is designed for OEM use and has no moving parts or obstructions in the flow path, so the measurement is independent of changes in temperature, pressure or viscosity. The liquid must have a conductivity above 20 µS/cm.

The sensor operates on the magnetic induction principle (Faraday's law). A magnetic field is generated inside the housing, and when the conductive liquid flows through the measuring tube a voltage is induced across the electrodes. This voltage is proportional to the average flow velocity and is converted into a flow-proportional frequency or analogue signal. A green LED indicates flow.

Accuracy is ±0.7 % of reading ±0.3 % of range, repeatability ±1 %, and response time is less than 100 ms. The sensor is supplied with 12 to 24 V DC and consumes at most 3.6 W. Outputs are a frequency signal in push-pull, NPN open collector or PNP open collector form, or an analogue 0.5 to 10 V signal. The electrical connection is a 4-pin M12 plug, with a 10 m cable and M12 coupling sockets available.

Models in the series cover inner diameters from 0.12 to 0.98 in, for example FMG93B, FMG96B, FMG98B, FMG915B, FMG920B and FMG925B. Wetted materials include PVDF, 316L stainless steel, POM, EPDM and FKM, with PTFE lining and EPDM liner options. Process connections are NPT from 3/8" to 1¼" or BSP. Maximum operating pressure is 145 psi; the process temperature range is 14 to 140 °F and the ambient operating range 41 to 140 °F. The enclosure is rated IP65, and the sensor is CE, UKCA and RoHS compliant.

Installation requires suitable gaskets and correct flow direction. For highest accuracy, a straight inlet section of 10 × ID and an outlet section of 5 × ID are recommended, and the maximum tightening torque is 3.7 ft·lb.

Stated applications are water treatment, chemical processing, pulp measurement and HFO outlet purifiers. Please send the liquid and its conductivity, flow range, pipe size, wetted material and output required with your enquiry.

Part numbers · 7

FMG93B, FMG96B, FMG98B, FMG915B, FMG920B, FMG925B, FMG915B-SS-IO-BSP

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU