Surent G480
Flow

Turbine & positive displacement meters
The FT-110 series is a low-cost, high-accuracy turbine flow sensor designed for OEM applications that require low-flow liquid monitoring. It measures the flow of water, coolant and other low-viscosity liquids and is built as a miniature unit that can be mounted in any orientation, with a lightweight plastic or brass body.
The liquid drives a turbine rotor, whose rotation is detected by a Hall-effect sensor. The sensor provides a frequency output proportional to the flow rate. Because the measurement is based on rotor speed, the output is not affected by pressure changes caused by aging filters in the system.
The series covers flow rates from 0.13 to 9.2 GPM (0.5 to 35 l/min) in several ranges, for example 0.13–1.3 GPM at 26,100 pulses per gallon, 0.13–2 GPM at 17,800 pulses per gallon and 0.53–2.1 GPM at 15,900 pulses per gallon. Accuracy is ±3 % of reading, both in the standard range and at low flow. The maximum operating pressure is 200 psi, and the operating temperature range is −20 to 212 °F (−29 to 100 °C). Filtration of 50 µm is recommended upstream.
The output is an NPN sinking open collector rated 20 mA maximum, and the sensor is supplied with 5 to 24 V DC at 8 mA. Electrical termination is available as a 3-pin DIN connector with 9.4 mm spacing (mating connector sold separately), spade terminals or a 3 ft, 24 AWG three-conductor PVC cable.
Bodies are made of brass or nylon 12, with wetted materials including nylon 12, PTFE with 15 % graphite, PA12 and brass. Process connections are 3/8" NPT male, G3/8 or a 17 mm tube O-ring design for manifold mounting. The sensor weighs 227 g and refers to NSF/ANSI/CAN 61. A mating DIN connector (212404) and cable assemblies (218572) are available separately, and special customised OEM versions can be discussed.
Please send the liquid, flow range, required connection, body material and electrical termination, and the expected quantities for OEM supply.
173932-C, 173933-C, 173932, 173935-C, 173936-C, 173933-D, 244425-D, 245148-C, 244426-C, 244422-D, 245149-D, 173934-D, 245148-D, 173940-2C, 173933, 191081, 173940, 173931-C-10, 244424-C, 173934-C, 244421-D, 244423-C, 173931-C, 173935-D, 173940-C, 173936-D, 244421-C, 173938-C, 173938-D, 173937-C, 173937-D, 244422-C, 173939-C, 173939-D, 244425-C, 234265-C, 234265-D, 244426-D, 234266-C, 234266-D, 218572, 212404
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.