Surent G480
Flow

Thermal mass meters & flow controllers
The GF100 series comprises metal-sealed thermal mass flow controllers and meters for high-purity process gas delivery. They are designed for semiconductor and MOCVD applications. Controllers measure and regulate the gas flow; meters measure only.
The instruments work on the thermal mass flow principle, and the flow path is sealed entirely with metal seals and finished to 5 or 10 µin Ra. The sensor is made of corrosion-resistant Hastelloy. MultiFlo technology allows thousands of gas types and ranges to be programmed without removing the device from the gas line, so a controller can be re-ranged or switched to another gas in place.
The standard GF series covers 3 sccm to 55 slpm, and the high-flow GF series 55 to 300 slpm. For both, accuracy is ±1 % of setpoint from 35 to 100 % and ±0.35 % of full scale from 2 to 35 %. The turndown is 2–100 % for the standard and 5–100 % for the high-flow series. Repeatability is ±0.15 % of setpoint from 5 to 100 % and ±0.015 % of full scale from 0.2 to 5 %. Long-term zero stability is better than ±0.5 % of full scale per year, and settling times range from 300 ms to less than one second. Maximum pressure is 500 psi and operating temperature 10 °C to 50 °C.
Connectivity includes analogue signals, RS-485 and DeviceNet, with 9-pin D, card-edge and RJ11 connectors. Process connections are available as C-seal, VCR male or W-seal fittings. A local display and a diagnostic port are provided. The GF120XSD is a Safe Delivery System (SDS) version for sub-atmospheric gases, and a high-temperature model is available for up to 150 °C. Further models are GF101, GF120, GF120XSL, GF121, GF125 and GF126.
The series is designed as a drop-in replacement and upgrade for most brands of metal-sealed mass flow controllers. It is supplied with an EU Declaration of Conformity and complies with EU REACH.
Listed applications are semiconductor etch tools, thin-film chemical vapour deposition systems (CVD, MOCVD, PECVD, ALD), physical vapour deposition (PVD), epitaxial process systems and advanced strip processes.
For selection, please send the gas, the flow range, the inlet pressure, the required fitting and the communication interface, and the controller you want to replace if applicable.
GF100, GF101, GF120, GF120XSD, GF120XSL, GF121, GF125, GF126
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.