The HX400 series is a programmable, two-wire loop-powered field transmitter for remote and on-site monitoring of relative humidity and temperature in air and neutral gases. It combines the functions of a transmitter, an indicator and alarm outputs in one unit: the measured values are converted, displayed, transmitted and switched as linearised, temperature-compensated 4–20 mA signals to remote receivers.
Measurement is based on a digital polymer capacitive humidity sensor and a silicon temperature sensor in a probe of 15.5 mm diameter, protected by a stainless steel wire mesh filter with 0.05 mm openings. Humidity is measured from 0 to 100 % RH with an accuracy of ±2 % RH, a repeatability of ±1 % RH and a resolution of 0.1 % RH. The response time is 10 s, and the reading rate is once per second. The operating temperature range is −40 to 100 °C.
The front carries a dual 3-digit high-brightness LED display, green for humidity and red for temperature, and three pushbuttons for configuration. Two-point field calibration lets the user adjust the transmitter on site against a reference. The outputs are 4–20 mA loops with an accuracy of ±0.02 mA, powered from 12 to 32 V DC; single and dual output models are available.
Six models cover the common mounting situations. HX401W, HX401R and HX401D are relative humidity transmitters for wall mounting, with a remote probe and for duct mounting. HX402W, HX402R and HX402D measure both relative humidity and temperature, with dual outputs, in the same three mounting styles. Depending on the version, enclosure ratings are IP40 or IP65 / NEMA 4. The housing measures 80 × 56 mm. The transmitters are CE marked and produced under ISO 9001.
Typical applications are environmental air monitoring, building systems, HVAC and ventilation control, clean-room and laboratory air, and storage and process rooms.
To select a model, please tell us whether humidity alone or humidity and temperature are required, the mounting style and the enclosure rating needed.
HX401W, HX401R, HX401D, HX402W, HX402R, HX402D
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.