UNILIGHT LED PPI
Controllers, recorders & signal conditioning

Process & PID controllers
The iLD-Series is a family of large-display digital panel meters and PID controllers intended for applications where a value must be read from a distance. Depending on the input model, the units serve for universal temperature monitoring, process measurement, strain gauge applications, AC current and voltage sensing, frequency, pulse and rate totalisation, or as a remote display fed by serial or Ethernet data.
The display uses 7-segment LED digits with a height of 57.2 mm (2.25 in) or 101.6 mm (4.00 in), in 4-digit or 6-digit configurations. Its colour can be programmed to switch between red, amber and green at set points or alarm conditions, so that the state of the process is visible at a glance across a hall or production line.
Temperature models accept thermocouples of types J, K, T, E, R, S, B, C, N and L to ITS 90 and platinum RTDs of 100, 500 and 1000 Ω to ITS 68; process models accept current signals of 0 to 20 mA and voltage signals. Stated accuracy is ±0.5 °C for temperature and 0.03 % of reading. The A/D converter is of the dual-slope type, common mode rejection is 120 dB, and input impedance is 10 MΩ for 100 mV and 1 MΩ for 1 or 10 V DC ranges. Input models are designated UTP, SP, ACC, ACV and FP.
As controllers, the units operate in reverse (heating) or direct (cooling) mode with full PID control. Alarm modes include band, high/low, latching or non-latching, normally open or closed, and process or deviation alarms. With the -33 suffix two form C SPDT relays rated 3 A at 120/240 V AC are fitted. Communication options are Ethernet to IEEE 802.3 10Base-T with TCP/IP, ARP and HTTPGET and an embedded web server, as well as RS-232, RS-422, RS-485 and Modbus. Excitation voltage is optional in place of communication.
Isolation is 2300 V AC for one minute between power and input or output, and 500 V AC between inputs. Connections are made on screw terminals. The front is rated IP65 and NEMA Type 4, and the units can be mounted flush in a panel or on a surface using the included brackets. They are UL and cUL certified, RoHS compliant and designed to EN 61010.
When enquiring, please state the digit height and count, input type, required relays and communication interface.
iLD24-UTP, iLD44-UTP, iLD24-SP, iLD44-SP, iLD24-FP, iLD26-FP, iLD44-FP, iLD46-FP, iLD24-ACC, iLD44-ACC, iLD24-ACV, iLD44-ACV, iLD24-C2, iLD44-C2, iLD26-C2, iLD46-C2, iLD24-EI, iLD44-EI, iLD26-EI, iLD46-EI, 33, C24, C4EI, EI, FS
List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.