VVB3
Mechanical & physical measurement

Position sensors & encoders
The IN-081 is a non-contacting displacement sensor based on the eddy current principle, intended for monitoring rotating machinery. It measures relative shaft vibration, relative shaft displacement and rotor speed. Unlike classic proximity probe systems, it has the driver electronics built into the sensor, so a separate oscillator-demodulator and the matched extension cable are not needed.
The probe generates a high-frequency electromagnetic field at its tip. A metallic measuring surface, preferably 42CrMo4 steel, changes this field depending on its distance, and the integrated electronics convert the change into an output voltage proportional to the gap. The linear measuring range is 1.5 mm, or up to 2.4 mm in the extended range, and the frequency response extends from DC to 2600 Hz, which covers both the static shaft position and its dynamic vibration. Output noise is below 1 mV peak-to-peak up to 10 kHz.
The sensor is supplied with −18 to −30 V DC and draws about 20 mA. The output signal can be loaded with up to 15 mA. The thermal effect on span is below ±5 % at room temperature and below ±10 % over the operating temperature range of 0 to 110 °C.
The standard sensor length is 70 mm; variable lengths from 70 to 250 mm are available to reach the shaft through bearing housings. Mounting threads are M10 × 1 or 3/8-24 UNF. The shielded cable is integrated, 5 m long as standard and up to 15 m on request. Protection is IP54, and an optional lacquer coating improves resistance to humidity. The design complies with API 670 for machinery protection systems and DIN 45670 for shaft vibration measurement, and is CE and RoHS compliant.
The compact design simplifies installation and wiring. Please state the required sensor length, thread, cable length and target material in your enquiry.
IN-081
Include the sensing target, mounting clearance and direction of travel or force. Record the connector pinout from the existing device.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.