Sierra Instruments InnovaSonic 203
Sierra Instruments

InnovaSonic 203 clamp-on ultrasonic transit-time liquid flow meter

Ultrasonic flowmeters

Manufacturer
Sierra Instruments
Model
InnovaSonic 203
Instrument type
Ultrasonic flowmeters
Principle
transit-time ultrasonic, clamp-on
Pipe size
2 to 48 in (50 to 1200 mm)
Flow range
0.49 to 12 m/s (1.6 to 40 ft/s), bidirectional
Accuracy
±1.0 % of reading
Repeatability
±0.3 % of reading
Outputs
4–20 mA (max. 750 Ω); pulse 0–9999 Hz OCT; SPST relay
Communication
RS-232, RS-485, Modbus RTU
Power supply
10 to 36 V DC at 1 A
Display / keypad
2 × 20 character backlit LCD; 16 tactile keys
Transmitter
PC/ABS, NEMA 4X / IP65
Transducers
encapsulated, IP68
Cable length
9 m standard; 30 m max.
Ambient temperature
−10 to 50 °C
Operating temperature
0 to 60 °C
Approvals
CE; Ex d II BT4
Request a quote
Review enquiry

InnovaSonic 203 is an economical clamp-on ultrasonic flow meter for water and general liquid applications. The transducers are fastened to the outside of the pipe, so no pipe cutting is needed, and the meter can be installed during plant operation without process shutdown or leakage risk.

The meter uses the transit-time principle with digital signal processing. Ultrasonic signals are sent alternately with and against the direction of flow, and the difference in their travel times is used to determine the flow velocity. The measurement is independent of the conductivity of the liquid. Transducers are mounted in the V method on pipes of 50 to 400 mm and in the Z method on pipes of 400 to 1200 mm; the transducer spacing is calculated from the pipe parameters. Straight runs of 10 D upstream and 5 D downstream are required.

The meter covers pipe sizes from 2 to 48 inches (50.8 to 1200 mm) and bidirectional flow velocities from 0.49 to 12 m/s (1.6 to 40 ft/s). Accuracy is ±1.0 % of reading over this range, and repeatability ±0.3 % of reading.

Outputs are a 4–20 mA current loop with a maximum load of 750 Ω, a 0 to 9999 Hz open-collector pulse output and an SPST relay output. Digital communication is via RS-232 or RS-485 with Modbus RTU. The electronics are modular and can be upgraded in the field. The transmitter is operated with 16 tactile keys, 12 of them dual-function, and shows readings on a backlit 2 × 20 character alphanumeric LCD. Power supply is 10 to 36 V DC at 1 A.

The transmitter housing is PC/ABS rated NEMA 4X and IP65, and the encapsulated transducers are rated IP68. Standard cable length is 9 m (30 ft), with up to 30 m (100 ft) possible. The ambient temperature range is −10 to 50 °C, the operating range 0 to 60 °C, and humidity up to 99 % RH non-condensing. The transmitter weighs about 0.7 kg and each transducer about 0.4 kg. The meter carries CE marking, and an Ex d II BT4 approval is listed. A five-point NIST-traceable calibration certificate and pipe straps for larger pipes are available as options.

Listed applications are HVAC systems, irrigation, water and wastewater, water treatment facilities, rural water companies, cooling and heating liquids, leak detection and water conservation. Please send the pipe material, outside diameter, wall thickness, liquid and expected flow range with your enquiry.

Part numbers · 1

IM-203

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.