Type 8189
Level

Float & magnetic level indicators
The LS-1700 Series is a compact single-point level switch for liquid level monitoring in industrial and hydraulic systems. It is suited to water, oil and hydrocarbon applications and is configurable for OEM volumes, with 46 configured variants listed.
A float moves with the liquid level and actuates a hermetically sealed SPST reed switch, opening or closing the circuit at the switch point. The float is made of TFE and is spring-biased. The switch logic is reversible, so the same unit can be used as normally open or normally closed, and the switch can be installed from the top or from the bottom of the vessel.
The float has a diameter of 1 inch and the actuation level is 0.5 in. The minimum specific gravity of the liquid is 0.85. The reed switch is rated 20 VA. Depending on the version, the switch withstands a maximum pressure of 300 PSI or 1000 PSI, and the operating temperature range is −40 to 300 °F. For very low currents below about 5 mA, it should be noted that the contacts of a 20 VA reed switch may not be kept clean and switching may become unreliable.
Mounting is vertical with a 1/8" NPT male thread. The stem and mounting are TFE in the version described, while wetted materials across the range include brass, 316 stainless steel, TFE, 18-8 stainless steel, Buna N and epoxy. Electrical connection is by 24 in long 22 AWG polymeric leads. The switch weighs approximately 0.5 lb (227 g).
Variants differ in wetted materials, pressure rating and switch logic and are identified by part numbers such as 011-1700, 010-1701, 016-4045 or 01702.
Typical applications named for the LS-1700 are level monitoring of water and oils in industrial and hydraulic systems and in OEM equipment.
When enquiring, please give the medium, its specific gravity, operating pressure and temperature, required switch logic and wetted material, or simply the part number if known.
016-4045, 59271, 01702, 011-1700, 62914, 27980, 177911, 198830, 01701, 016-3433, 010-1701, 26791, 148691, 188886, 010-2921, 010-1194, 010-2922, 174795, 200284, 010-1636, 75860, 016-0907, 197500, 12972, 176259
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.