Gems Sensors & Controls LS-3
Gems Sensors & Controls

LS-3 single-point float level switch with reed contact

Float & magnetic level indicators

Manufacturer
Gems Sensors & Controls
Model
LS-3
Instrument type
Float & magnetic level indicators
Principle
float with magnet actuating a hermetically sealed reed switch
Switch type
SPST, 20 VA or 50 VA
Switch operation
normally open or normally closed, reversible by inverting the float
Voltage rating
120 to 240 V AC
Float diameter
0.625 to 1.86 in
Minimum specific gravity
0.45
Maximum pressure
15, 50 or 150 psi (150 psi at 70 °F)
Operating temperature
−40 to 250 °F
Float materials
polypropylene (solid or hollow), polysulfone, PVDF, Buna-N, nylon
Stem materials
polypropylene, polysulfone, nylon, PVDF
Mounting threads
1/8 in NPT male, 3/8-16 UNC, M12 × 1.75, G 1/8
Termination
24 in, 22 AWG PVC or PTFE leads, or 2-conductor PVC cable
Mounting orientation
vertical
Approvals
UL recognised, CSA, CE, RoHS; FDA-compliant materials, NSF on request
Request a quote
Review enquiry

The LS-3 series consists of compact single-point float level switches for detecting a liquid level in industrial and commercial applications. Their small size suits restricted spaces such as shallow tanks and compact systems, and they are designed for high-volume OEM use, for example in medical devices, compact appliances and food and beverage machines.

A float encircles a stationary stem and moves up and down with the liquid level. When it reaches the switching point, it actuates a hermetically sealed magnetic reed switch mounted inside the stem. The switch function can be chosen as normally open or normally closed simply by inverting the float. The reed-switch design is durable, resists shock and vibration and offers precise repeatability, with a deviation of no more than 1 %.

The switches are SPST types rated 20 VA or 50 VA, with voltage ratings from 120 V AC to 240 V AC. Float diameters range from 0.625 to 1.86 in, with actuation levels from about 0.375 to 0.81 in depending on the model. Liquids with a specific gravity as low as 0.45 can be detected. Pressure ratings of 15, 50 or 150 psi are available (150 psi at 70 °F), and the operating temperature range is −40 °F to 250 °F. The switch is mounted vertically.

Floats are available in solid or hollow polypropylene, polysulfone, PVDF, Buna-N and nylon, stems in polypropylene, polysulfone, nylon or PVDF; brass, epoxy and ceramic magnets are among the listed wetted materials. Mounting threads include 1/8 in NPT male, 3/8-16 UNC, M12 × 1.75 and G 1/8. Electrical termination is either 24 in long 22 AWG leads with PVC or PTFE insulation or a two-conductor PVC cable. Examples are the 209475 with a 1 in polypropylene float and 1/8-27 NPT thread, and the 209465 with a 1/2 in PVDF float and M12 × 1.75 thread.

The switches are UL recognised, CSA listed, CE declared and RoHS compliant. FDA-compliant materials are available, and NSF certification can be provided on request. Accessories include a slosh shield, and a low-level detection model is offered.

Listed media are water, potable water, water-based liquids, oils and chemicals.

When enquiring, please state the liquid, the required switch function, float and stem material, mounting thread and electrical termination.

Part numbers · 18

209475, 209465, 209460, 209455, 173250, 189786, 189787, 171514, 171517, 171518, 189739, 116826, 142505, 42295, 177818, 201540, 142545, 76707

Industry applications

Selection notes

Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment