Type 8189
Level

Float & magnetic level indicators
LS-800-5 is a single-point float level switch designed for external mounting on tanks where internal access is difficult or impossible. Instead of being inserted through the tank roof, the switch is fitted on the outside at the level to be detected, which saves space inside the tank. It suits large and small tanks and can be used to signal levels to remote alarms.
The unit mounts at the actuation point via 3/4" NPT ports, so the liquid in the tank also fills the switch chamber. A float rises and falls with the liquid and operates a reed switch. Switch operation is reversible: as standard the contact is normally open with the lead wires up, and it can be changed by inverting the float or by mounting the switch with the lead wires down.
The float is made of 316 stainless steel with a diameter of 2.0625 in and requires a minimum liquid specific gravity of 0.75. Actuation level is 3/4 in or 7/16 in depending on version. The switch is an SPST reed contact rated 20 VA or 100 VA; a DPDT switch is also offered. Electrical termination is by 24-inch 18 AWG polymeric leads.
The switch withstands pressures up to 750 psi, or 150 psi in some versions, and operates from −40 to 300 °F (−40 to 149 °C), with a 230 °F limit for certain versions. Ports and stems are available in brass or stainless steel; wetted materials include 316 stainless steel, H-15-7-MO stainless steel, brass and beryllium copper depending on version.
The switch is CSA approved and RoHS compliant to directive 2015/863/EU, with exceptions for specific brass parts. It is mounted vertically on the outside of the tank.
Typical uses stated for this switch are level monitoring on large or small tanks, industrial liquid level monitoring and remote alarms. Please send the liquid and its specific gravity, operating pressure and temperature, the required port material and switch rating with your enquiry.
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.