Surent G480
Flow

Water, gas & heat meters
The M140H is a multi-jet water meter for flush mounting, designed for sub-metering of cold or warm water. It is built as a hybrid measuring capsule: the mechanical multi-jet impeller is combined with tamper-proof electronic sensing and a fully electronic register with integrated wireless M-Bus communication, so consumption can be read remotely.
The movement of the rotor is detected directly by inductive sensing, and the electronic counter totalises the volume. The LCD shows up to 99,999.999 m³. Readings are transmitted over wireless M-Bus at 868.95 MHz to mobile receivers or gateways. The radio telegrams follow EN 13757-4 and OMS and can be encrypted with AES-128 in modes 5 and 7.
The nominal flow rate Q3 is 2.5 m³/h and the overload flow rate Q4 is 3.125 m³/h. The measuring range is R80 for horizontal and R40 for vertical installation. Accordingly, the transitional flow Q2 is 50 l/h horizontal or 100 l/h vertical, and the minimum flow Q1 is 31.25 l/h horizontal or 62.5 l/h vertical. The starting flow is 4 l/h. The meter is rated for 16 bar and mechanical class M1.
Variants are available with ingress protection from IP56 up to IP68. Dimensions are approximately 75 to 77 mm in width, with heights of about 65 to 80 mm depending on the H1 or H3 version. The meter conforms to MID 2014/32/EU, OIML R49 and EN ISO 4064, and for its radio part to RED 2014/53/EU and EN 13757; EMC 2014/30/EU, RoHS 2011/65/EU and WEEE 2012/19/EU are also stated.
A comprehensive portfolio of cartridges and convertors allows the meter to be fitted into existing flush-mounted installations. Cartridge interface types TE1, IST, MOC, MOE and MET are offered, together with convertors for A34, MB3, MUK, DM1, WE1, WGU and HT2 housings.
Installation must be carried out by competent persons in accordance with DIN 1988, DIN EN 806, DIN EN ISO 4064 and guideline DVGW-W406. For an accurate offer, please tell us whether the meter is for cold or warm water, the existing flush-mounted housing or interface type, the installation position and the required ingress protection.
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.