Electromagnetic flowmeters
Measuring principle
electromagnetic (Faraday's law)
Measuring ranges
from 0.01–0.5 l/min to 35–700 l/min
Span
up to 50:1
Accuracy
±2 % of full scale
Process connection
G 1/2 to G 2 3/4 male thread
Materials
PPS/stainless steel, PVDF/Hastelloy, tantalum
Electrodes
stainless steel, Hastelloy or tantalum
Maximum pressure
10 bar
Maximum temperature
80 °C
Temperature measurement
integrated Pt1000
Communication
IO-Link
Outputs
pulse, frequency, alarm, analogue 4–20 mA (configurable)
Display
TFT, rotatable in 90° steps
Approvals
cCSAus, IECEE CB scheme, EMC, RoHS
Request a quote
Review enquiry

The MIK is an electromagnetic flow meter and monitor for measuring and monitoring the flow of electrically conductive liquids in pipes. Media named include water, groundwater, cooling water and wastewater, as well as neutral and aggressive media such as corrosive acids and alkalis. It is used for flow control, flow measurement, filling and quantity recording in the food, chemical, paper and construction industries.

The instrument works according to Faraday's law of induction: when the conductive liquid moves through a magnetic field, a voltage proportional to the flow rate is induced in it. This voltage is picked up and processed by the compact U-PACE electronics. Measurement is bidirectional, and an integrated Pt1000 sensor measures the medium temperature at the same time.

Measuring ranges extend from 0.01–0.5 l/min in the smallest version up to 35–700 l/min in the largest, with a measuring span of up to 50:1. Accuracy is ±2 % of full scale. The meter is rated for a maximum pressure of 10 bar and a maximum medium temperature of 80 °C.

The electronics provide IO-Link for connection to automation systems and configurable outputs for pulse, frequency, alarm and analogue signals. Versions include the MIK-…C3T0 compact electronics with a TFT display that can be rotated in 90° steps, the MIK-…F3 with frequency output and the MIK-…L4 with analogue output. A dosing function with an external control input is provided for filling tasks. The stainless steel design can be operated with gloves.

Wetted material combinations are PPS with stainless steel, PVDF with Hastelloy, or tantalum, and electrodes are available in stainless steel, Hastelloy or tantalum, so that the meter can be matched to neutral or aggressive liquids. Process connections are male threads from G 1/2 to G 2 3/4.

The meter carries cCSAus (ORDLOC) and IECEE CB scheme approvals, conforms to the EMC Directive to EN IEC 61326-1:2021 and to RoHS to EN IEC 63000:2018.

When enquiring, please state the liquid, flow range, pressure, temperature, connection size, material combination and the required outputs.

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.