Brooks Instrument MT3809
Brooks Instrument

MT3809 metal tube variable area flow meter for gas and liquid

Variable area flowmeters

Manufacturer
Brooks Instrument
Model
MT3809
Instrument type
Variable area flowmeters
Measuring principle
variable area, metal tube
Media
gas, liquid
Flow range
water to 440 gpm (100,000 l/h); air to 750 scfm (1200 m³n/h)
Accuracy
±1 % FS (class 1.6), ±2 % FS (class 2.5), ±3 % FS, ±5 % FS (class 4) to VDI/VDE
Repeatability
0.25 % FS (1 % FS for ELF)
Turndown
10:1
Operating temperature
−198 to 420 °C
Max. operating pressure
1379 bar
Analogue outputs
4–20 mA, 0–20 mA, 0–10 V, 0–5 V
Digital communication
HART, FOUNDATION Fieldbus
Protection
IP65, IP66, IP67, NEMA 4X
Hazardous area
Class 1 Div 1/2, Zone 1/2; ATEX, IECEx, CSA, UL, NEPSI, KOSHA
Other
SIL; NACE and 3.1 material traceability
Request a quote
Review enquiry

The MT3809 series is a metal tube variable area flow meter for reliable measurement of gas and liquid flow in demanding industrial applications. The meter can be configured from a simple mechanical indicator to an electronic transmitter with digital communication.

The meter works on the variable area principle: a float in a tapered metering tube is lifted by the flow until the forces acting on it are in balance, so its height is a measure of flow rate. In a metal tube the float position is transmitted to the indicator outside the tube. Indication is available in mechanical or electronic form, with alarms and control options; electronic versions provide a digital display and a local operator interface.

Maximum flow is 440 gpm (100,000 l/h) for water and 750 scfm (1200 m³n/h) for air. Accuracy options are ±1 % FS (class 1.6 to VDI/VDE), ±2 % FS (class 2.5), ±3 % FS and ±5 % FS (class 4); repeatability is 0.25 % FS, or 1 % FS for the ELF option. Turndown is 10:1. The meter operates from −198 to 420 °C and at pressures up to 1379 bar.

Analogue outputs of 4–20 mA, 0–20 mA, 0–10 V and 0–5 V are available, and digital communication via HART and FOUNDATION Fieldbus. Ingress protection is IP65, IP66 or IP67 and NEMA 4X depending on version.

Hazardous-area approvals cover Class 1 Division 1 and Division 2, Zone 1 and Zone 2, with ATEX, IECEx, CSA, UL, NEPSI and KOSHA certification; the meter is also SIL rated and REACH compliant. Multiple materials and process connections are available, material traceability to NACE and 3.1 level can be provided, and custom engineered special versions are possible.

Stated applications include oil and gas production, chemical processing, refining, power generation and flare stack measurement. Please send the medium, flow range, pressure, temperature, required accuracy class, output and area classification with your enquiry.

Part numbers · 98

3809G-A-07-F-1-B-0, 3809G-A-07-F-1-H-0, 3809G-A-07-H-5-A-0, 3809G-A-07-G-6-H-0, 3809G-A-07-J-1-D-0, 3809G-A-08-F-1-C-0, 3809G-A-10-F-1289-A-0, 3809G-A-10-F-1289-A-A, 3809G-A-10-F-1-B thru U-0, 3809G-A-10-G-1-A-0, 3809G-A-10-H-1-A-0, 3809G-A-10-H-5-A-0, 3809G-A-10-J-3-D-0, 3809G-A-10-J-3-B-0, 3809G-A-12-F-1-B thru U-0, 3809G-A-12-F-2-A-0, 3809G-A-12-G-6-D-3-0, 3809G-A-12-J-3-B-0, 3809G-A-12-J-2-A-0, 3809G-A-13-F-1-A-0, 3809G-A-13-F-1-C-0, 3809G-A-13-F-3-D-0, 3809G-A-15-F-1-A-0, 3809G-A-13-F-8-A-0, 3809G-A-15-H-2-A-0, 3809G-A-15-J-3-B-0, 3809G-A-16-J-2-A-0, 3809G-A-16-J-3-B-0, 3809G-A-D-07-B-1-B-0, 3809G-B-05-F-3-D-0, 3809G-B-07-Q-3-D-0, 3809G-B-08-F-8-A-0, 3809G-B-10-F-1289-A-0, 3809G-B-08-H-1-A-0, 3809G-B-10-F-1289-A-AB, 3809G-B-10-G-1-A-0, 3809G-B-12-F-3-4-0, 3809G-B-12-F-6-D-3-0, 3809G-B-13-F-1289-A-0, 3809G-B-13-F-3-D-0, 3809G-B-C-07-J-0, 3809G-C-02-F-3-D-C, 3809G-C-03-F-1-A-A, 3809G-C-07-F-1-A-0, 3809G-C-07-F-1-A-A, 3809G-C-07-G-2-A-0, 3809G-C-08-F-3-H-0, 3809G-C-08-F-1-B-0, 3809G-C-08-F-6-D-3-0, 3809G-C-08-G-3-H-0, 3809G-C-08-F-8-A-0, 3809G-C-08-J-3-D-0, 3809G-C-10-F-1-A-0, 3809G-C-10-F-3-H-0, 3809G-C-10-G-3-D-0, 3809G-D-00-B-3-D-3-B, 3809G-D-0102030405-ABCD-1289-A-0, 3809G-D-0102030405-ABCD-1-BCDEFGMNPQ-0, 3809G-D-0102030405-ABCD-3-BCDEFGMNPQ-EF, 3809G-D-0102030405-A-3-D-0, 3809G-D-0102030405-A-1-A-0, 3809G-D-0708-ABCD-1289-A-0, 3809G-D-0708-ABCD-1-BCDEFGHJKL-AB, 3809G-D-07-ABCD-1289-A-A, 3809G-D-07-A-2-A-0, 3809G-D-07-B-1-A-B, 3809G-D-08-A-1-C-0, 3809G-D-08-AB-1289-A-A, 3809G-D-08-A-3-D-B, 3809G-D-08-AB-1289-A-C, 3809G-D-08-ABCD-3-BCDEFGMNPQ-0, 3809G-D-08-B-1-A-0, 3809G-D-10-A-1-A-B, 3809G-D-10-AB-1289-A-A, 3809G-D-10-A-1-D-B, 3809G-D-10-ABCD-1289-A-0, 3809G-D-12-A-1-A-0, 3809G-D-12-A-1-BCDEFGMNPQ-0, 3809G-D-12-B-1-A-0, 3809G-E-05-B-1-A-0, 3809GE07B1A0 GP, 3809G-E-08-ABCD-3-BCDEFGMNPQ-0, 3809G-E-10-A-1-A-0, 3809G-E-10-AB-3-BCDEFGMNPQ-0, 3809G-E-10-B-2-A-0-0, 3809G-E-10-B-3-D-0, 3809G-E-12-A-1-A-0, 3809G-E-12-B-3-D-0, 3809G-F-0708-E-1289-A-0, 3809G-F-10-E-5-A-0, 3809G-G-08-B-1-A-0, 3809G-J-08-F-3-D-0, 3809G-H-07-F-1-A-0, 3809G-J-08-G-3-D-0, 3809G-J-08-F-3-H-0, 3810G-A-12-F-1-A-0, 3810G-A-07-F-1-A-A, 3809G-D-13-AB-1289-A-0

Industry applications

Selection notes

State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU