Type 8189
Level

Float & magnetic level indicators
The NBK is a bypass level indicator for the continuous measurement, display and monitoring of liquid levels. It is used on tanks, vessels, reservoirs, basins, storage tanks, agitator vessels, water tanks and tanks on ships. The bypass chamber is made of stainless steel 1.4571.
The indicator works without direct contact between the medium and the display. A float with embedded magnets moves with the liquid level inside the bypass tube. Its magnetic field rotates magnetic rollers or balls in the external display, and can also actuate limit switches or transmitters mounted on the tube.
A single-part indicator has a measuring length of up to 5500 mm; longer lengths are built as two-part or multipart versions. Accuracy is ±10 mm and repeatability ±5 mm. Nominal pressures are PN 40 or ASME Class 150/300, with others on request up to PN 320. The permitted medium temperature depends on the display: −20 to +400 °C with ceramic rollers, −20 to +120 °C with POM rollers and −104 to +200 °C with the ball display; models NBK-31, -32 and -33 cover −60 to +100 °C. Standard maximum viscosity is 200 mm²/s, with 460 mm²/s as an option for the NBK-03.
The nominal size is typically DN 25 or 1/2". Process connections include DIN flanges DN 15 to DN 50, ASME flanges 1/2" to 2", R and NPT threads and welding nipples; flanges follow EN 1092, ANSI B16.5 and DIN 2512. Ambient temperature is −20 to +80 °C for the metal design and 0 to +50 °C for the plastic design, and ingress protection is IP54, IP65 (optional), IP66 or IP67.
For remote signalling, limit switches (NBK-RA, NBK-RE, NBK-RD) and transmitters with 4–20 mA, HART, PROFIBUS PA, PROFIBUS DP, Foundation Fieldbus or Loop Link 5905 are offered. Display variants are roller displays (RP, RK) and ball displays (KP, KM, KF, KG).
The indicator is ATEX-approved for hazardous areas, with markings such as II 1/2G Ex h IIC T4…T1 Ga/Gb and, with intrinsically safe components, II 1GD Ex ia IIC T6 Ga. CE, DNV and RoHS are also listed, together with the pressure equipment directive 2014/68/EU. In hazardous areas installation must be carried out by trained staff, and potential equalisation is required.
Please send the measuring length, medium, density, pressure, temperature, process connection and required switches or transmitter with your enquiry.
NBK-03, NBK-06, NBK-07, NBK-10, NBK-31, NBK-32, NBK-33, NBK-RA, NBK-RE, NBK-RD
Identify the vessel height, nozzle position and surface conditions. A point alarm and a continuous level reading require different outputs.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.