Surent G480
Flow

Water, gas & heat meters
The NXU is a smart ultrasonic gas meter for residential natural gas metering. It combines ultrasonic flow measurement with safety functions – an integrated remote shutoff valve and a pressure transducer – and communicates over the cellular network, supporting residential gas measurement, safety monitoring and leak detection.
Flow is measured by ultrasonic time-of-flight: ultrasonic pulses are sent with and against the gas flow, and the difference in transit time gives the flow velocity. The meter has no moving parts in the measuring path, and from the ultrasonic measurement it also infers the density of the gas composition. Readings are temperature-compensated. The pressure transducer and the shutoff valve allow the meter to detect leaks or abnormal conditions and to trigger alerts or shut off the gas supply.
The meter has a multirange capacity of 250/425 CFH, with 425 CFH at 0.5 in. WC, and a maximum allowable operating pressure of 10 psig (690 mbar). Measurement temperature is −34 to 60 °C; the valve operates from −25 to 55 °C and the index and storage range is −40 to 70 °C. The leakage rate of the closed valve is at most 0.035 CFH at 2 psig differential. The LCD shows consumption in CCF with a resolution of 0.001 CCF. The meter is suitable for natural gas according to EN 437 types H, E and L (test gases G20, G21, G23, G25, G26).
Communication is via cellular AMI (automated meter infrastructure) using CAT-M with NB-IoT fallback on bands 2, 4, 12 and 13; an eUICC allows remote SIM provisioning. Power comes from lithium thionyl chloride D cells with a battery life of up to 20 years.
The case is die-cast aluminium with a single-coat polyester finish, and the meter weighs 6 lb. It is rated for Class I, Division 1, Group D, temperature class T1, and complies with ANSI B109.6, ASME B16.33 and FCC Part 15. Connection sizes 10 LT, 20 LT, 30 LT, 1 in Pitts and 1 in Sprague are available.
The listed part numbers are AC250NXU, AC250NXUR110 and AC250NXUR120.
For an offer, please state the part number, the connection size and the number of meters required.
AC250NXU, AC250NXUR110, AC250NXUR120
State the minimum, normal and peak flow with units. Pipe bore, fluid properties and the available straight run affect the choice of measuring principle.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.