DwyerOmega OM-CP-PRTEMP140
DwyerOmega

OM-CP-PRTEMP140 submersible high-temperature pressure and temperature data logger

Recorders & data loggers

Manufacturer
DwyerOmega
Model
OM-CP-PRTEMP140
Instrument type
Recorders & data loggers
Measured values
pressure and temperature
Pressure sensor
strain gauge
Pressure range
0 to 5 bar
Pressure accuracy (calibrated)
±0.03 bar; resolution 0.0001 bar
Temperature sensor
RTD
Temperature range
−20 to 140 °C
Temperature accuracy
±0.1 °C (20 to 140 °C), resolution 0.01 °C
Memory
32,767 readings
Sampling rate
1 Hz
Battery
user-replaceable Li-ion, up to 2 years
Interface
USB via docking station
Versions
flush top (LVL) or 1/8 NPT pressure port (NPT)
Protection
IP68
Weight
90 g
Request a quote
Review enquiry

The OM-CP-PRTEMP140 series is a submersible data logger for high-temperature and pressure environments. It records temperature and pressure simultaneously in a rugged stainless steel body rated IP68, and operates at temperatures up to 140 °C. Applications named for it are autoclave validation, mapping studies and pressurised processes.

Pressure is measured with a strain gauge sensor and temperature with an RTD. The logger stores up to 32,767 time-stamped readings and samples at up to 1 Hz. After the recording, the data is retrieved through a USB interface, using the OM-CP-IFC400 USB docking station or the OM-CP-IFC406 multiplexer interface. Calibration is digital and is carried out through the software.

The pressure range is 0 to 5 bar with a resolution of 0.0001 bar and a calibrated accuracy of ±0.03 bar. Temperature is measured from −20 to 140 °C with a resolution of 0.01 °C and an accuracy of ±0.1 °C between 20 and 140 °C. The operating pressure range is stated as 0.002 to 100 psi, and the logger operates from −20 to 140 °C.

Power comes from a user-replaceable Li-ion battery with a life of up to two years. The logger weighs only 90 g. CE and RoHS conformity (RoHS 2015/863) is stated, and the software is available in a version compliant with FDA 21 CFR Part 11.

Two mechanical versions are offered: a flush top version (LVL) and a version with a 1/8 NPT pressure port (NPT). Each can be ordered with a NIST calibration certificate, indicated by the -CERT suffix, for example OM-CP-PRTEMP140-LVL-CERT or OM-CP-PRTEMP140-NPT-CERT.

The docking station or multiplexer interface is required for data extraction and is ordered in addition to the logger. When you send an enquiry, please specify the version with flush top or NPT port, whether a calibration certificate is needed, how many loggers are required and whether you need the USB docking station or the multiplexer interface.

Part numbers · 4

OM-CP-PRTEMP140-LVL, OM-CP-PRTEMP140-LVL-CERT, OM-CP-PRTEMP140-NPT, OM-CP-PRTEMP140-NPT-CERT

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU