DwyerOmega OM7
DwyerOmega

OM7 series modular isolated signal conditioners for data acquisition

Signal conditioners & barriers

Manufacturer
DwyerOmega
Model
OM7
Instrument type
Signal conditioners & barriers
Input types
thermocouple J, K, T, E, R, S, B, N; Pt and Ni RTD; mV, V, mA; potentiometer; 2-wire transmitter
Output ranges
1–5 V, 0–10 V, 4–20 mA, 0–20 mA
Accuracy
±0.1 % of span typical, factory calibrated
Non-linearity
±0.02 %
Isolation
1500 Vrms, channel-to-channel
Input protection
120 V rms
Bandwidth (−3 dB)
3 Hz to 400 Hz, selectable
Input bias current
1 nA
Output resistance
< 1 Ω, short-circuit protected
Supply
24 V DC nominal
Module size
54 × 42 × 14 mm
Operating temperature
−40 to 85 °C
Humidity
90 % non-condensing
Mounting
OM7-BP backplanes (1–16 channels), 35 mm DIN rail or 19″ rack
Approvals
CE, UL, UKCA, RoHS
Request a quote
Review enquiry

The OM7 series is a modular, isolated signal conditioning system for data acquisition and process control. Single-channel plug-in modules accept analogue signals from field sensors and convert them into isolated, high-level analogue outputs that can be read by data acquisition hardware, controllers or recorders.

Each module filters, isolates, amplifies, linearises or converts its input signal. Modules are available for voltage, current, RTD, thermocouple, potentiometer and two-wire transmitter inputs, including thermocouple types J, K, T, E, R, S, B and N and platinum and nickel RTDs. Outputs are 1–5 V, 0–10 V, 4–20 mA or 0–20 mA. True channel-to-channel isolation of 1500 Vrms gives high common mode voltage rejection, and the bandwidth can be selected between 3 Hz and 400 Hz to filter out noise.

The modules are factory calibrated to an accuracy of ±0.1 % of span (typical) with non-linearity of ±0.02 %. Inputs are protected up to 120 V rms, input bias current is 1 nA and input resistance ranges from 2 MΩ to 100 kΩ depending on the module. The output resistance is below 1 Ω, and outputs are protected against short circuit to ground.

All modules run from a nominal 24 V DC supply and share a common pinout, so different types can be mixed on one backplane. The design is hot-swappable: modules can be removed and inserted with power applied. Each module measures 54 × 42 × 14 mm. Backplanes of the OM7-BP series hold 1, 2, 4, 8 or 16 channels, connect to the acquisition system through a 25-pin D-type male connector, and can be installed on 35 mm DIN rail or in a 19-inch rack with the OM7-RK002 kit.

The operating and storage range is −40 to 85 °C at up to 90 % relative humidity, non-condensing. The modules carry CE, UL and UKCA marking and are RoHS compliant.

Typical applications are data acquisition systems, temperature monitoring, process control and industrial automation in industrial environments, where field signals must be isolated and standardised before digitising. Listed module types include OM7-21, OM7-22 and OM7-30 to OM7-34.

Please send a list of your input signals and required output ranges, together with the number of channels and the mounting method, and we will compile the matching modules and backplanes.

Part numbers · 139

OM7-21, OM7-22, OM7-30, OM7-31, OM7-32, OM7-33, OM7-34, OM7-34-N, OM7-35, OM7-36, OM7-37, OM7-39, OM7-40, OM7-41, OM7-47, OM7-BP-01-C, OM7-BP-01-C-DIN, OM7-BP-1-C, OM7-BP-1-DIN-C, OM7-BP-16-C, OM7-BP-16-DIN-C, OM7-BP-2-C, OM7-BP-2-DIN-C, OM7-BP-4-C, OM7-BP-4-DIN-C, OM7-BP-8-C, OM7-BP-8-DIN-C, OM7-BP-EV, OM7-CA-01, OM7-CA-02, OM7-DIN-CP, OM7-DIN-SE, OM7-DIN-SF, OM7-DIN-WSF, OM7-IF, OM7-PROTO, OM7-RI, OM7-RK002, OM7-30-01-1-C, OM7-30-01-2-C, OM7-30-02-1-C, OM7-30-02-2-C, OM7-30-03-1-C, OM7-30-03-2-C, OM7-30-05-1-C, OM7-30-05-2-C, OM7-30-06-1-C, OM7-30-06-2-C, OM7-30-07-1-C, OM7-30-07-2-C, OM7-30-08-1-C, OM7-30-08-2-C, OM7-31-01-1-C, OM7-31-01-2-C, OM7-31-02-1-C, OM7-31-02-2-C, OM7-31-03-1-C, OM7-31-03-2-C, OM7-31-04-1-C, OM7-31-04-2-C, OM7-32-01-1-C, OM7-32-01-2-C, OM7-32-02-1-C, OM7-32-02-2-C, OM7-33-01-1-C, OM7-33-01-2-C, OM7-33-02-1-C, OM7-33-02-2-C, OM7-34-01-1-C, OM7-34-01-2-C, OM7-34-02-1-C, OM7-34-02-2-C, OM7-34-03-1-C, OM7-34-03-2-C, OM7-34-04-1-C, OM7-34-04-2-C, OM7-34-05-1-C, OM7-34-05-2-C, OM7-34-N-01-1-C, OM7-34-N-01-2-C, OM7-34-N-02-1-C, OM7-34-N-02-2-C, OM7-35-01-1-C, OM7-35-01-2-C, OM7-37-J-01-1-C, OM7-37-J-01-2-C, OM7-37-J-10-1-C, OM7-37-J-10-2-C, OM7-37-J-11-1-C, OM7-37-J-11-2-C, OM7-37-J-12-1-C, OM7-37-J-12-2-C, OM7-37-J-13-1-C, OM7-37-J-13-2-C, OM7-37-K-02-1-C, OM7-37-K-02-2-C, OM7-37-K-20-1-C, OM7-37-K-20-2-C, OM7-37-K-21-1-C, OM7-37-K-21-2-C, OM7-37-K-22-1-C, OM7-37-K-22-2-C, OM7-37-K-23-1-C, OM7-37-K-23-2-C, OM7-37-T-03-1-C, OM7-37-T-03-2-C, OM7-37-E-04-1-C, OM7-37-E-04-2-C, OM7-37-R-05-1-C, OM7-37-R-05-2-C, OM7-37-S-06-1-C, OM7-37-S-06-2-C, OM7-37-B-07-1-C, OM7-37-B-07-2-C, OM7-39-01-C, OM7-39-02-C, OM7-47-J-01-1-C, OM7-47-J-01-2-C, OM7-47-J-02-1-C, OM7-47-J-02-2-C, OM7-47-K-03-1-C, OM7-47-K-03-2-C, OM7-47-K-04-1-C, OM7-47-K-04-2-C, OM7-47-T-05-1-C, OM7-47-T-05-2-C, OM7-47-T-06-1-C, OM7-47-T-06-2-C, OM7-47-E-07-1-C, OM7-47-E-07-2-C, OM7-47-R-08-1-C, OM7-47-R-08-2-C, OM7-47-S-09-1-C, OM7-47-S-09-2-C, OM7-47-B-10-1-C, OM7-47-B-10-2-C, OM7-47-N-11-1-C, OM7-47-N-11-2-C, U24Y175

Industry applications

Selection notes

List input types and the destination of each output. Match panel cutout, supply and communication options before choosing a replacement.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.