DwyerOmega OXY-FLEX
DwyerOmega

OXY-FLEX zirconia oxygen analyser

Oxygen analysers

Manufacturer
DwyerOmega
Model
OXY-FLEX
Instrument type
Oxygen analysers
Sensor
zirconium dioxide (zirconia)
Measured value
oxygen partial pressure, % O₂
Ranges
0.1–25 % or 0.1–100 % O₂, configurable
Accuracy after calibration
1 % O₂
Repeatability after calibration
0.5 % O₂
Response time
< 15 s
Gas temperature
−100 to +250 °C or −100 to +400 °C
Max. pressure
3 bar
Gas flow rate
0 to 10 m/s
Outputs
4–20 mA (0.01 mA); 0–10 V DC (0.01 V)
Digital interface
RS232, 0.01 % O₂ resolution
Supply voltage
24 V DC ± 10 %
Warm-up / stabilisation
60 s / approx. 180 s
Probe length
220 mm or 400 mm
Request a quote
Review enquiry

OXY-FLEX is an oxygen analyser for high-accuracy linear oxygen measurement. It is built around a robust zirconium dioxide sensor element for long-term reliability, is installed as a probe, and needs no reference gas. Measuring ranges and outputs can be configured to suit the application.

The analyser measures the partial pressure of oxygen (PPO₂) in the measured gas with its zirconia sensor and converts it into a linear signal over the full measuring range. Output filtering can be selected either for fast response or for stable monitoring. Calibration can be carried out in fresh air or at known oxygen concentrations, and an external trigger input allows calibration to be started automatically or manually.

Two measuring ranges can be configured: 0.1 to 25 % O₂ or 0.1 to 100 % O₂. After calibration, accuracy is 1 % O₂ and repeatability 0.5 % O₂. The response time is below 15 seconds. After switching on, the sensor warms up in 60 seconds, and the output is stable after about 180 seconds. The analyser tolerates gas pressures up to 3 bar, gas flow velocities from 0 to 10 m/s and repetitive accelerations of 5 g.

The wide gas temperature range is a characteristic of the analyser: depending on the version it is rated from −100 °C to +250 °C or from −100 °C to +400 °C. The probe is available in lengths of 220 mm and 400 mm, and it has a steel body.

The analyser is supplied with 24 V DC ± 10 %. It provides a 4–20 mA output with 0.01 mA resolution, a 0–10 V DC output with 0.01 V resolution and an RS232 digital interface with a resolution of 0.01 % O₂, so the measured value can be passed to a controller, recorder or computer.

Wiring instructions must be followed carefully, as incorrect wiring can cause permanent damage. The sensor should not be exposed to silicone vapours or chemical cleaning agents.

Listed applications are oxygen analysis and process monitoring. Please send the gas temperature, required range, probe length and output signal with your enquiry so that the matching version can be selected.

Industry applications

Selection notes

Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU