BARTEC P-800LT
BARTEC

P-800LT online freeze point process analyser

Process gas analysers & chromatographs

Manufacturer
BARTEC
Model
P-800LT
Instrument type
Process gas analysers & chromatographs
Measured value
freeze point (disappearance of last wax crystals)
Operating range
−125 to 25 °C (−193 to 77 °F)
Detection
automatic optical, straight-path absorbance and 90° back-scatter
Method
correlates with ASTM D2386
Measuring cycle
typically less than 15 minutes
Repeatability
less than 0.25 °C (0.5 °F)
Cooling
internal cryo chiller to −125 °C
Analogue outputs
freeze point, cell temperature, optical signals
Digital outputs
freeze point alarm, analyser fault, come read (programmable)
Digital inputs
customer alarm, remote standby, stream switch, validation (dry contact)
Communication
Modbus TCP/IP or serial Modbus RTU
Display
7-inch colour graphics
Ex protection
cCSAus Class I Div. 1 Groups B, C, D; ATEX Ex II 2G Ex db IIB T6 Gb; IECEx Ex db IIB T6 Gb
Dimensions
approx. 940 × 1803 × 762 mm
Weight
approx. 340 kg
Request a quote
Review enquiry

The P-800LT is an online freeze point process analyser. It determines the freeze point of a sample, defined as the temperature at which the last wax crystals disappear, directly at the process instead of in the laboratory. It is designed for the oil and gas and chemical industries and is built in explosion-protected form for installation in hazardous areas.

The analyser cools the sample in a measuring cell and then watches the crystals with automatic optical detection, using straight-path absorbance and 90° back-scatter (absorbance or reflectance). Cooling is provided by an internal cryo chiller that reaches −125 °C without any external cooling system. The results correlate with the laboratory method ASTM D2386. No sample recovery system is needed.

The operating range is −125 °C to 25 °C (−193 °F to 77 °F). A typical measuring cycle takes less than 15 minutes, and repeatability is better than 0.25 °C (0.5 °F). Two designations are listed: P-800LT and P-800LT-1.00.

Analogue outputs transmit the freeze point, the cell temperature and the optical signals. Programmable digital outputs signal a freeze point alarm, an analyser fault and the “come read” status. Dry-contact digital inputs accept a customer alarm, remote standby, stream switching and a validation request. Modbus communication is available over TCP/IP or as serial Modbus RTU, and remote diagnostics over IP are supported. Local operation uses a 7-inch colour graphic display.

The analyser carries cCSAus approval for Class I, Division 1, Groups B, C and D, ATEX marking Ex II 2G Ex db IIB T6 Gb and IECEx marking Ex db IIB T6 Gb. It is a cabinet-sized unit of approximately 940 × 1803 × 762 mm and weighs about 340 kg.

Options include a sample conditioning system, a fast loop pump and sample probes, and consulting and engineering services are available for the integration into the plant.

Listed sectors are oil and gas, chemical, pharmaceuticals, energy, manufacturing and logistics, hydrogen and food and beverages.

To prepare an offer, please send the product to be analysed, the expected freeze point range, the sample conditions at the take-off point, the area classification and the required outputs.

Part numbers · 2

P-800LT, P-800LT-1.00

Industry applications

Selection notes

Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.