LDH313
Gas analysis

Dew point & moisture analysers
PMA-5674 is a process trace moisture analyser for accurate and stable measurement of very low moisture levels in gases and liquids. It uses optical fibre-based sensor technology and is designed for demanding process conditions such as high pressure and hazardous areas.
The measurement is based on a Fabry-Pérot interferometer. The moisture sensor is connected to the evaluation and control unit by a fibre-optic combined cable, and the optical signal is evaluated to determine the moisture content. The optical sensor technology provides long-term measurement stability and reliable detection of trace moisture even at very low levels.
The calibrated dew point range is −80 °C to +20 °C with an accuracy of ±1 K dew point. Results can be displayed and output in ppmv, ppmw, dew point, frost point, relative humidity, mg/m³, lbs/mmscf or water vapour pressure. The sensor can be operated at process pressures up to 20 MPa (2900 psi), and it is suitable for natural gas/hydrogen mixtures and pure hydrogen.
The analyser is available as a single-channel or multi-channel unit with 1, 2 or 3 sensor channels for multi-point measurement. For connection to control systems it offers Modbus RTU over RS-485, Modbus TCP/IP over Ethernet with remote access, six analogue outputs (0/4–20 mA) and six potential-free changeover relays.
The evaluation and control unit operates from 5 to 50 °C with AC supply or 5 to 45 °C with DC supply. The fibre-optic combined cable is rated from −20 to 70 °C, optionally −55 to 70 °C, and the moisture sensor from −30 to 60 °C. The control unit is marked ATEX II (1)G [Ex ia op is IIC Ga] and IECEx [Ex ia op is IIC Ga]; the sensor is marked II 1/2 G Ex ia IIC T6 Ga/Gb (ATEX) and Ex ia IIC T6…T3 Ga/Gb (IECEx).
An emission-free in-line sensor retraction system allows maintenance without process shutdown. Installation options include direct installation, Union-T installation, a gas/liquid separator, a sensor retraction assembly and standard or customised sample conditioning systems. Process-near sensor calibration and validation is available.
Listed applications are natural gas processing, LNG production, petrochemical processes, hydrogen infrastructure and specialty gas systems. Please send the medium, pressure, expected moisture range, number of measuring points and preferred installation with your enquiry.
PMA-5674
Identify the target gas, background gas and concentration units. State whether the sampling system is already installed or belongs in the enquiry.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.