Optris PI 640i CM
Optris

PI 640i CM infrared camera package for condition monitoring and early fire detection

Pyrometers & thermal cameras

Manufacturer
Optris
Model
PI 640i CM
Instrument type
Pyrometers & thermal cameras
Detector
uncooled bolometer, 640 × 480 pixels, 17 µm pitch
Spectral range
8–14 µm
Frame rate
32 Hz
Thermal sensitivity (NETD)
40 mK
Temperature ranges
−20…100 °C, 0…250 °C, 150…900 °C; optional 200…1500 °C
Accuracy
±2 °C or ±2 %, whichever is greater
Optics (FOV)
15° × 11°, 33° × 25°, 60° × 45°, 90° × 64°
Visible camera
HD video module, 1280 × 720 pixels
Interface
Ethernet via USB server Gigabit (PoE)
Direct I/O
1 × 0/4–20 mA output, 1 analogue or digital input, optically isolated
Process interface (option)
2 × 0–10 V in, digital in, 3 × 0/4–20 mA out, 3 relays, fail-safe relay
Housing
aluminium, IP66, ZnS window, air purge, heater and fan
Operating temperature
−40 to 50 °C
Dimensions
485 × 140 × 265 mm
Weight
2 kg (2.5 kg with wall bracket)
Request a quote
Review enquiry

The PI 640i CM is a pre-configured infrared camera package for continuous thermal condition monitoring and early fire detection in tough industrial and outdoor settings. It is supplied pre-assembled in an outdoor housing with a wall mount, ready for installation.

The package combines a thermal camera with an uncooled bolometer detector of 640 × 480 pixels and a built-in HD video module with 1280 × 720 pixels. The thermal camera works in the 8–14 µm spectral range with a pixel pitch of 17 µm, a frame rate of 32 Hz and a thermal sensitivity (NETD) of 40 mK.

Object temperature ranges are −20…100 °C, 0…250 °C and 150…900 °C, with 200…1500 °C as an option. Accuracy is ±2 °C or ±2 % of reading, whichever is greater. Four optics are available, with fields of view of 15° × 11°, 33° × 25°, 60° × 45° and 90° × 64°.

The camera is connected over Ethernet through a USB server Gigabit with PoE, which enables integration into video management and SCADA systems. Directly on the camera there is one optically isolated 0/4–20 mA analogue output and one analogue or digital input. The optional industrial process interface adds two 0–10 V inputs, a digital input up to 24 V, three 0/4–20 mA outputs, three relays rated 0–30 V / 400 mA and a fail-safe relay, for example for alarm triggering. The supplied software is included.

The sturdy aluminium outdoor housing is rated IP66 and is fitted with a ZnS protective window, an air purge collar and a built-in heater and fan. The package operates from −40 to 50 °C and can be stored from −40 to 70 °C. It measures 485 × 140 × 265 mm and weighs 2 kg, or 2.5 kg with the wall mount bracket. Shock and vibration tests to IEC 60068-2-27, IEC 60068-2-6 and IEC 60068-2-64 are listed, along with CE, UKCA, RoHS and EMC 2014/30/EU.

Order variants differ by optics, from 15° to 90°; industrial air purge and the wall mounting bracket are available as options. Applications named for the package are substations, coal and biomass conveyor systems, waste facilities, lumber yards and storage bunkers. Please send the distance to the monitored area, the required field of view and the temperature range with your enquiry.

Part numbers · 4

OPTPI64ILTCMO15T090, OPTPI64ILTCMO33T090, OPTPI64ILTCMO60T090, OPTPI64ILTCMO90T090

Industry applications

Selection notes

Match the sensing element, insertion length and wiring to the existing input. Separate the process temperature from the ambient temperature at the connection head.

For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.

For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.

Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.

Related instruments

Find equipment

DEVICEEU