EDT 96
Pressure

Pressure switches
The PS75 series is a general purpose pressure switch for heavy-duty applications in which high pressure surges occur. Its piston/diaphragm design combines the high proof pressure of a piston switch with the sensitivity of a diaphragm, so the switch reacts reliably to its set point while withstanding pressure peaks in the system.
Pressure acts on the diaphragm and piston, which move against the set spring and operate the electrical contact when the switch point is reached. A wear disc and a cushioning ring increase service life under surging conditions, and all-metal surfaces serve as overload stops, so excessive pressure is taken by the metal parts rather than by the sensing element. The switch point can be adjusted in the field or set at the factory.
Pressure ranges cover 10 to 4350 psi, which corresponds to 0.7 to 300 bar. The operating temperature range is −30 to 121 °C (−22 to 250 °F). Contact configurations are SPDT, SPST normally closed and SPST normally open, with a switch rating of 5 A; gold contacts are available as an option for low-energy circuits.
Wetted pressure fittings are offered in 316 stainless steel, 12L14 zinc-plated steel or brass, and the diaphragm can be ordered in nitrile, FKM (Viton), neoprene or EPDM to suit the medium. Electrical termination options include a DIN 43650A connector with a 9 mm cable clamp in straight or right-angle form, a DIN 43650A male half only, and flying leads; pressure connections include 1/2" NPT. The switch housing is protected to IP65, and the series carries CE and UL approvals.
Eight standard part numbers are listed for the series, for example 626022, 625979 and 204680, covering different ranges, materials and terminations. The switch is intended for general purpose industrial applications and for systems with high pressure surges.
Please send the required switching pressure, the medium, the preferred fitting and diaphragm material, the circuit type and the electrical termination with your enquiry.
626022, 625979, 626004, 204680, 209554, 209924, 625992, 214113, 626069, 209965, 625983, 229323, 625927, 626005, 207690, 213416, 626030, 625956, 625972, 219726, 626071, 233302, 210854, 211254, 626037
Specify whether the reference is gauge, absolute or differential pressure. Include the normal span and the largest pressure the instrument may see.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.