EDT 96
Pressure

Pressure transmitters
The PX835 series comprises intrinsically safe, explosion-proof and flame-proof pressure transmitters for hazardous industrial locations. They measure vacuum, compound and gauge pressure and are used on oil field equipment, in upstream oil and gas production, for natural gas compression and transfer control, in alternative energy projects and in fuel cell manufacturing.
The transmitters combine a modern pressure sensor with digital calibration, which gives a linear and precise output over the specified pressure and temperature ranges. The sensor sits behind a 316 stainless steel diaphragm and pressure port, inside an all-welded 304 stainless steel case. Ranges extend from vacuum and compound ranges up to 100 psi to gauge ranges up to 10,000 psi.
Accuracy is ±0.5 % of total pressure (TP) and ±0.40 % BFSL, including non-linearity, hysteresis, non-repeatability and zero and span setting errors. Long-term stability is ≤ ±0.25 % of span per year, the position effect is ±0.02 % typical, and the response time is 2 ms. The transmitters operate with process and ambient temperatures from −40 to 125 °C and are temperature compensated from −20 to 85 °C. Insulation resistance is 100 MΩ.
The output is a 2-wire 4–20 mA signal. The standard electrical connection is a 1/2″ NPT male conduit fitting with pigtail or flying leads, and the pressure connection is 1/4″ NPT male. Options include a shielded cable, a 4-pin bayonet connector (Bendix style, shell size 8) and oxygen cleaning with the suffix -X6B.
The enclosure is rated IP65, NEMA Type 7 and NEMA Type 9. For hazardous areas, the transmitters are approved for Class I, Division 1 and 2, Groups A, B, C and D and Class II, Division 1 and 2, Groups E, F and G, with ATEX marking II 2 GD Ex d IIC T4 and Ex nC IIC T4; non-incendive Class I, Division 2 ratings also apply. The series carries ATEX, FM and cULus approvals and is CE, UKCA and RoHS compliant.
When requesting a quotation, please state the pressure range and type (gauge, vacuum or compound), the electrical connection and the hazardous area classification of the installation.
PX835-15NGI, PX835-015CGI, PX835-030CGI, PX835-045CGI, PX835-060CGI, PX835-100CGI, PX835-005GI, PX835-010GI, PX835-015GI, PX835-030GI, PX835-060GI, PX835-100GI, PX835-150GI, PX835-200GI, PX835-300GI, PX835-500GI, PX835-750GI, PX835-1KGI, PX835-1.5KGI, PX835-2KGI, PX835-3KGI, PX835-5KGI, PX835-7.5KGI, PX835-10KGI
Specify whether the reference is gauge, absolute or differential pressure. Include the normal span and the largest pressure the instrument may see.
For an installed instrument, copy the complete ordering code and its suffixes from the nameplate. Identify the part that will remain in service and the part that needs to be replaced. A photograph of the connection face or terminal markings helps resolve differences between versions that share the same housing.
For a new installation, describe what the instrument must measure or control and where the reading will be used. Give the normal operating conditions separately from short peaks. Include units with every numerical value. A drawing with the available space, orientation and access for removal gives the supplier a practical starting point.
Add the quantity for each position and identify any accessories that belong with it. Where a particular drawing, material certificate or calibration record is required, mention it with the line item. Submit the list with the destination country so that the response can cover the requested configuration and delivery.